1 . Error Display and How to Take a Measure
233
MF-C2000A Series
Chapter 2 Inspection and Measure T
o Be T
aken at Occurrence of an Error
Introduction Part
Operating Part
Maintenance Part
Appendixes
Installation
and
Preparation
Part
Chapter 2
●
Inspection and Measure To Be
Taken at Occurrence of an Error
1 . Error Display and How to Take a Measure
When an error occurs in the laser, the contents of the error are displayed on
the laser controller screen as shown below . In the following, how to take a
measure is explained in the order of Error No . At occurrence of an error, read
this chapter carefully and perform inspection of the laser and take a proper
measure .
* If you have any unclear point, contact the distributor or us for information.
⇒
When there is any related page in this Operation Manual, the reference page is
shown.
Main Unit
LD "-":
State of LD doesn’t change even if an error/fault occurs.
LD "OFF":
LD is turned off automatically if an error/fault occurs.
Alarm output "-":
Error/Fault signal is not output if an error/fault occurs.
Alarm output "ON":
Error/Fault signal is output if an error/fault occurs.
Maintenance Part
Error No .
Contents of the error
(Troubles are displayed up to
ten occurrences .)
Содержание MF-C2000A Series
Страница 1: ...AA04OM1209213 07 FIBER LASER WELDER MF C2000A Series OPERATION MANUAL ...
Страница 21: ...Introduction Part ...
Страница 22: ......
Страница 34: ......
Страница 42: ......
Страница 43: ...Installation and Preparation Part ...
Страница 44: ......
Страница 73: ...Operating Part ...
Страница 74: ......
Страница 78: ......
Страница 142: ......
Страница 208: ...208 MF C2000A Series 4 Connector Functions REM I L Connector E STOP Connector Refer to the Operating Part Chapter 4 ...
Страница 212: ......
Страница 213: ...Maintenance Part ...
Страница 214: ......
Страница 232: ......
Страница 244: ......
Страница 245: ...Appendixes ...
Страница 246: ......