106
MF-C2000A Series
4 . Setting the Laser Light Output Schedule
4 . Setting the Laser Light Output Schedule (MF-C2000A-
M/S Only)
On the SCHEDULE screen, the laser light output schedules are set and registered by
giving SCHEDULE numbers.
If a registered SCHEDULE number is entered, the corresponding output schedules
can be called.
The setting items of laser output time and laser output value are different between
fixed waveform (FIX) and flexible waveform (
FLEX / CW).
SCHEDULE Screen (Fixed Waveform (FIX))
How to see the displayed items
: Settable item
SET POWER
Sets the laser output. Regarding "FLASH1" to "FLASH3", set the ratio (%) sup-
posing that the set value is the reference value (100%). Refer to “REFERENCE
VALUE” for the forecast value of laser output.
<Note>
The settable value of laser output is 200 to 2000.
MIN
The ratio of the preliminary oscillation output for "SET POWER" is displayed.
For the preliminary oscillation, see page 108.
SLOPE
Sets the up-sloping (the laser output becomes gradually stronger) time to
"FLASH1."
After setting "FLASH1", set this time in the range of
SLOPE ≤ FLASH1.
<Note>
The setting and the slope may be different in a low output range of 0 to 200 W.
Check the waveform output on the monitor. To make more detailed settings, use
the FLEX mode.
Содержание MF-C2000A Series
Страница 1: ...AA04OM1209213 07 FIBER LASER WELDER MF C2000A Series OPERATION MANUAL ...
Страница 21: ...Introduction Part ...
Страница 22: ......
Страница 34: ......
Страница 42: ......
Страница 43: ...Installation and Preparation Part ...
Страница 44: ......
Страница 73: ...Operating Part ...
Страница 74: ......
Страница 78: ......
Страница 142: ......
Страница 208: ...208 MF C2000A Series 4 Connector Functions REM I L Connector E STOP Connector Refer to the Operating Part Chapter 4 ...
Страница 212: ......
Страница 213: ...Maintenance Part ...
Страница 214: ......
Страница 232: ......
Страница 244: ......
Страница 245: ...Appendixes ...
Страница 246: ......