background image

4

Chapter

Operation

Содержание BreezeMAX PRO 5000 CPE

Страница 1: ...BreezeMAX PRO 5000 CPE Product Manual Software Version 1 5 April 2010 P N 215643...

Страница 2: ...ry 2010 ATPC Parameters on page 72 Added a note that the DHCP Client can be set to disable only in ETH CS service The upload procedure of a country codes file country_codes xml was added The country c...

Страница 3: ...l Removed SW Version 1 5 March 2010 Aligning the PRO CPE s External Antenna on page 39 New section SW Version 1 5 March 2010 Integratiion Time Removed SW Version 1 5 March 2010 Configuration Control o...

Страница 4: ...m is a registered trademark of the WiMAX Forum WiMAX the WiMAX Forum logo WiMAX Forum Certified and the WiMAX Forum Certified logo are trademarks of the WiMAX Forum Statement of Conditions The informa...

Страница 5: ...n AS IS basis Alvarion its affiliates or its licensors MAKE NO WARRANTIES WHATSOEVER WHETHER EXPRESS OR IMPLIED WITH RESPECT TO THE SOFTWARE AND THE ACCOMPANYING DOCUMENTATION ALVARION SPECIFICALLY DI...

Страница 6: ...NG UNDER BREACH OF CONTRACT TORT INCLUDING NEGLIGENCE STRICT LIABILITY OR OTHERWISE AND WHETHER BASED ON THIS AGREEMENT OR OTHERWISE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES b TO THE EXTENT...

Страница 7: ...rm any servicing unless you are qualified to do so Line Voltage Before connecting this instrument to the power line make sure that the voltage of the power source matches the requirements of the instr...

Страница 8: ...ns associated with or caused by installation grounding or lightning protection Disposal of Electronic and Electrical Waste Disposal of Electronic and Electrical Waste Pursuant to the WEEE EU Directive...

Страница 9: ...nished under a license The software may be used or copied only in accordance with the terms of that license Information in this document is subject to change without notice Corporate and individual na...

Страница 10: ...CPE and its specifications Chapter 2 Installation Describes how to install the PRO 5000 CPE Chapter 3 Commissioning Describes how to configure basic parameters align the antenna and validate unit ope...

Страница 11: ...2 6 Environmental 7 1 2 7 Standards Compliance General 8 1 2 8 Physical and Electrical 9 Chapter 2 Installation 10 2 1 Installing the ODU of the CPE 12 2 1 1 CPE Installation Requirements 12 2 1 2 Gu...

Страница 12: ...PRO CPE s External Antenna 39 3 5 Operation Verification 40 Chapter 4 Operation 41 4 1 Introduction to CPE Management 43 4 2 Accessing the Web Configuration Server 44 4 3 Using the Web Configuration...

Страница 13: ...Show 72 4 9 2 ATPC 73 4 10 Performance Monitor 76 4 10 1 Link Quality Counters Page 76 4 10 2 Ethernet Counters 77 4 11 Service Parameters 79 4 12 Management Parameters 82 4 12 1 Management Parameters...

Страница 14: ...del 19 Figure 2 6 Ethernet Connector Pin Assignments 21 Figure 2 7 Inserting the IDU COM Cable into the Sealing Cap 22 Figure 2 8 CPE IDU 1D Front Panel 24 Figure 2 9 CPE IDU 1D 3D View 24 Figure 2 10...

Страница 15: ...72 Figure 4 15 Multi rate and ATPC Parameters Page 73 Figure 4 16 Link Quality On line Display Page 76 Figure 4 17 Ethernet Counters Page 77 Figure 4 18 Service Page IP CS Mode Show Parameters 79 Figu...

Страница 16: ...iance Specifications 8 Table 1 9 Mechanical Specifications 9 Table 1 10 Electrical Specifications 9 Table 1 11 Connectors 9 Table 2 1 Approved Category 5E Ethernet Cables 14 Table 2 2 CPE ODU PRO Conn...

Страница 17: ...Tables BreezeMAX PRO 5000 CPE xvii Product Manual Table 4 3 CPE Parameters Summary 85...

Страница 18: ...1 Chapter Product Description...

Страница 19: ...Chapter 1 Product Description BreezeMAX PRO 5000 CPE 2 Product Manual In This Chapter Introducing BreezeMAX PRO 5000 CPEs on page 3 Specifications on page 5...

Страница 20: ...mple XTRM SU OD 1D 4 9 6 E The units support the TR 069 CPE WAN Management Protocol CWMP allowing efficient management by an Auto Configuration Server ACS In addition configuration and performance mon...

Страница 21: ...carrying the Ethernet data between the two units as well as power 54 VDC and control signals to the ODU and status indications from the ODU A miniature SU Alignment Unit SAU that includes signal stre...

Страница 22: ...than 30 dBm then the Maximum EIRP can vary by more than 3 dB As regulations in most countries limit the EIRP of units operating in the 5 4 GHz band it is recommended to use detached anten nas up to an...

Страница 23: ...Hz BW QPSK 1 2 96 93 QPSK 3 4 93 90 16QAM 1 2 89 86 16QAM 3 4 86 83 64QAM 2 3 81 78 64QAM 3 4 80 77 64QAM 5 6 79 76 Table 1 3 ODU ODU Communication Item Details Cable Type Category 5E Outdoor Data Cab...

Страница 24: ...ess Password Allocation of IP parameters WAN DHCP options 43 60 66 67 Software upgrade HTTP TFTP Configuration Upload Download HTTP TFTP Authentication TTLS Table 1 6 Environmental Specifications Item...

Страница 25: ...quired for antenna stability under operation Table 1 8 Standard Compliance Specifications Type Standard EMC FCC Part 15B Class B EN 55022 Class B EN 301 489 1 4 Safety UL 60950 1 22 IEC EN 60950 1 22...

Страница 26: ...le 1 10 Electrical Specifications Item Details Power Consumption 16 5W CPE IDU Power Input 100 240 VAC 47 63 Hz CPE ODU PRO Power Input 54 VDC or 48VDC from the IDU over the indoor outdoor Ethernet ca...

Страница 27: ...2 Chapter Installation...

Страница 28: ...Chapter 2 Installation BreezeMAX PRO 5000 CPE 11 Product Manual In This Chapter Installing the ODU of the CPE on page 12 Installing the IDU 1D Indoor Unit of the CPE on page 23...

Страница 29: ...l software utilities and User Guide CD IDU Package CPE IDU unit comprising of AC power adapter and internal gateway Power Cable Package AC DC power cable CAUTION ONLY experienced installation professi...

Страница 30: ...ials including appropriate means e g a 1 to 4 pole for installing the ODU and antenna where applicable 2 1 1 3 Optional Items Tilt Pole Mounting kit 2 1 2 Guidelines for Positioning the ODU This secti...

Страница 31: ...on That is in the same time the same CPE cannot connect to multiple BTSs It is the responsibility of the operator and the installer to take into account that at least in the 5725 5850 MHz band the equ...

Страница 32: ...stalling the unit using either vertical or horizontal polarization The clamp enables installing the unit on diverse pole diameters from 1 to 4 A Tilt Pole Mounting kit providing a tilt range of 15 is...

Страница 33: ...sing a screwdriver Install the unit with the bottom panel which includes the connectors facing downward You can install the ODU with the arrow on the back of the unit facing upwards or rightwards Matc...

Страница 34: ...Chapter 2 Installation Installing the ODU of the CPE BreezeMAX PRO 5000 CPE 17 Product Manual Figure 2 2 ODU Pole Installation Using the Special Clamp Arrow Facing Rightwards...

Страница 35: ...g the two pairs of flat washers spring washers and nuts supplied in the Tilt kit 2 Mount the Tilt accessory on a 1 to 4 pole using two 9 16 metal bands 3 Release slightly the Tilt Control Screw tilt t...

Страница 36: ...nd of a grounding cable to the grounding screw and tighten the grounding screw firmly Figure 2 4 Bottom Panel of the ODU SA SE model without sealing covers Figure 2 5 Top Panel of the ODU SE model Tab...

Страница 37: ...nected to the unit to ensure good sealing Pull back the shield drain wire before inserting the cable into the RJ 45 connector to ensure a good connection with the connector s shield after crimping The...

Страница 38: ...lvarion are as listed in the following table 1 The seal has a special groove allowing to insert an ethernet cable with an already assembled RJ 45 connector Strip the cable sheath and crimp the RJ 45 p...

Страница 39: ...p 8 Route the cable to the location selected for the indoor equipment 9 Assemble an RJ 45 connector with a protective cover on the indoor end of the IDU ODU cable Refer to the pin assignment and color...

Страница 40: ...plug adapter or termination plug if the power plug on the supplied AC power cord does not fit local power outlets For configuring parameters a Portable PC Notebook and a straight Ethernet cable for co...

Страница 41: ...3 1 CPE IDU 1D Connectors and LEDs Figure 2 8 CPE IDU 1D Front Panel Figure 2 9 CPE IDU 1D 3D View Table 2 4 CPE IDU 1D Connectors Name Connector Functionality ETHERNET 4 on the side panel 10 100Base...

Страница 42: ...5 CPE IDU 1D LEDs Name Description Functionality POWER 3 Power Indication Off IDU is not powered or power failed Green IDU power is OK ETH 2 Ethernet link status Ethernet integrity Off No Ethernet con...

Страница 43: ...ion 2 1 6 2 for instructions on preparing the cable Figure 2 10 XTRM SU IDU 1D Table 2 6 XTRM SU IDU 1D Connectors Name Connector Functionality LAN 10 100Base T RJ 45 with 2 embedded LEDs Connection t...

Страница 44: ...t the POWER LED located on the front panel is lit indicating that the unit is supplying power to the radio port 6 Configure the basic parameters and align the antenna as described in the applicable se...

Страница 45: ...r grounding the outdoor rated Category 5E Ethernet cable through its drain wire The actual connection method employed is left to the professional installer 1 Strip back about a one inch 2 4 cm section...

Страница 46: ...3 Chapter Commissioning...

Страница 47: ...oning BreezeMAX PRO 5000 CPE 30 Product Manual In This Chapter Commissioning Steps on page 31 Configuring Basic Parameters on page 32 Aligning the PRO CPE s Internal Antenna on page 35 Operation Verif...

Страница 48: ...rformed to ensure connectivity with a BTS and provisioning of services After the CPE is connected with a BTS it can be fully managed via the wireless link 1 The basic parameters must be configured to...

Страница 49: ...ly if Ethernet Auto Negotiation Enable Disable is set to Disable User Name CPEMACaddress WiMax com Should be supplied by system administrator operator User Password Empty Should be supplied by system...

Страница 50: ...he CPE using a straight Ethernet cable 2 Configure the PC s IP parameters to enable connectivity with the unit The IP address of the CPE for local management access is 192 168 254 251 The Subnet Mask...

Страница 51: ...required parameters configuration and performance monitoring options Refer to Chapter 4 for instructions on using the Web Configuration Server and detailed information on the various parameters and ot...

Страница 52: ...s of antenna alignment and provide the ODU s status indications 1 Remove the sealing cap of the ODU s SAU connector 2 Connect the cable attached to the SAU to the SAU connector 3 After completing the...

Страница 53: ...detected between the outdoor unit and the device connected to the indoor unit s Ethernet port WLNK Wireless link status indication Off The SU is not connected with a BS Orange on The SU is connected...

Страница 54: ...toward the general direction of the BTS 2 Connect the SAU to the ODU 3 Verify that the PWR power indication on the SAU is on 4 Verify that the WLNK LED indicator is on indicating that the unit is syn...

Страница 55: ...ving the expected link quality try to improve the reception quality by placing the ODU at a higher point or in an alternate location 6 Secure the ODU firmly to the pole NOTE Ensure that the front of t...

Страница 56: ...he expected link quality try to improve the reception quality by placing the antenna at a higher point or in an alternate location 3 Secure the ODU antenna firmly to the pole To align the external ant...

Страница 57: ...to the end user s data equipment examine the Ethernet Integrity and Ethernet Activity LEDs of the Ethernet connectors To verify data connectivity from the end user s PC or from a portable PC connecte...

Страница 58: ...4 Chapter Operation...

Страница 59: ...44 Using the Web Configuration Server on page 45 Show All on page 46 Unit Control Parameters on page 47 Registration Parameters on page 59 BST AU Parameters on page 63 Radio Parameters on page 67 ATP...

Страница 60: ...server as a part of the Network Entry process The DHCP server should supply also the IP address of the ACS management station In the uplink the DSCP value of management packets sent by the unit can b...

Страница 61: ...192 168 254 251 The Subnet Mask is 255 255 255 0 The recommended IP address for the PC is 192 168 254 250 as this is also the default TFTP Sever IP Address required for downloading SW versions and fo...

Страница 62: ...to the same menu item Several pages include a Current Parameters area and a Configured Parameters area The Current Parameters area displays the current unit s settings To change the settings of the pa...

Страница 63: ...nables viewing all the configurable parameters of the unit In addition the displayed information includes the general hardware and software properties of the units and relevant status details The disp...

Страница 64: ...nformation as follows HW Details CPE Type CPE Pro SQ CPE Family Describes the primary chipset of the CPE Sequans Serial Number Describes the serial number of the CPE unit This number can be used to de...

Страница 65: ...rameters and status Ethernet Port Auto Negotiation Mode Enable Disable Ethernet Port Speed and Duplex Ethernet Down Timeout Duration in seconds after which the system is up again Operation Mode IP CS...

Страница 66: ...ame in the TFTP server of the SW version to be downloaded to the unit Configuration File Upload Name the name of the configuration file to be uploaded Configuration File Download Name the name of the...

Страница 67: ...hange the login password Enter the old password the new password and re enter the new password for confirmation Then click Save New Password Click Refresh to clear the fields Valid passwords 1 to 20 p...

Страница 68: ...n The typical process of upgrading to a new SW version includes the following steps 1 Download the new SW file to the CPE It will be stored as the Shadow version 2 Reset and run the unit from its Shad...

Страница 69: ...s is 192 168 254 250 You can enter a new TFTP Server IP address Remote TFTP Server IP address the IP address of the WAN TFTP server used for SW version download SW File Name the name in the TFTP serve...

Страница 70: ...o reset the unit and run the Shadow version after power up To avoid unintentional actions you will be prompted to confirm the request Set Running Version as Main when the unit is running the Shadow ve...

Страница 71: ...Name consists of up to 50 characters The default Configuration File Download Name is SU_DOWNLOAD_CFG Local TFTP Server IP Address enter the IP address of the LAN TFTP server The default TFTP Server I...

Страница 72: ...ile as called in the TFTP server or country code file as provided by 4Motion as the Configuration File Download Name 4 Select Download in the Choose Upload Download Action field 5 Click Perform Action...

Страница 73: ...Unlimited by purchasing a license Following are the available licenses From 2 to Unlimited From 2 to 6 From 6 to Unlimited The License Control page includes the following fields buttons License Downlo...

Страница 74: ...51 4 5 7 Ethernet Operation Op Mode The Ethernet Port control parameter enables viewing and defining the operation mode of the Ethernet port The Ethernet Operation Mode page includes the following fi...

Страница 75: ...MAX PRO 5000 CPE 58 Product Manual 100Mbps Full Duplex Ethernet Down Timeout applicable only in IP CS Enables to configure Ethernet downtime after which it will be up again The range is from 3 seconds...

Страница 76: ...n for security reasons User Name Configured and Current the name of the unit to be used for service provisioning Changes to the User Name parameter are applied only after reset Therefore the actual va...

Страница 77: ...ayed A message that informs about rebooting the unit is also so that the changes made will take effect User Name consists of 1 to 32 printable characters case sensitive The default User Name is CPEMAC...

Страница 78: ...ptional and is intended for optional use by the Network Management System The Country name can include up to 12 printable characters Authentication A security supplicant incorporated into the device s...

Страница 79: ...Chapter 4 Operation Registration Parameters BreezeMAX PRO 5000 CPE 62 Product Manual mode and will complete the network entry without EAP TTLS authentication process The default is EAP TTLS...

Страница 80: ...th The range used for scanning is defined by the BS ID and BS ID Mask parameters The initial range can be limited by defining a preferred range of BSs and selecting the best BS in the preferred range...

Страница 81: ...f loosing the link connection the CPE will Wait 4 minutes if BS is preferred or preferred mask is not set Go directly to scanning if BS is not preferred and mask is set The BST AU page includes the fo...

Страница 82: ...the mask is 255 255 255 255 255 255 and the CPE finds it in the discrete frequency list or in the full range it will immediately connect to it Selected BST AU Parameters Selected BST AU ID The BST AU...

Страница 83: ...mobility of the CPE Nomadic or Mobile The default is Nomadic After configuring the parameters click Apply to save your changes Preferred BS Loss Timeout before trying to connect to a preferred BS This...

Страница 84: ...uring the scanning process The list of frequencies that participate in the scanning process includes a set of frequencies belonging to the scanning range and or a set of up to 10 discrete frequencies...

Страница 85: ...4 1 Intermediate Steps Step Effect on scanned frequencies set when Step is Enabled B0 Scan Start Frequency Start Frequency is added to the set of Main Frequencies B1 Intermediate Step 125 KHz All inte...

Страница 86: ...e following fields Scanning Table displays the list of all current frequencies that participate in the full scanning process Following the Full Scanning Table the Best BS Scanning Table displays all t...

Страница 87: ...he frequencies to be scanned between the Start and End Rx Frequencies The Intermediate Scanning Steps include 8 Steps that define the intermediate scanning steps as described above The default is Enab...

Страница 88: ...un time without resetting the unit Clear Best BS Table select this option to clear the current Best BS Table Typically this should be done prior to initiating a full scanning process see below Force F...

Страница 89: ...not be saved and will automatically return to original values as received from the BS when the unit resets or upon closing the web interface The ATPC menu includes the following sub menus Show ATPC 4...

Страница 90: ...band The default Tx Power is the last power level used before the ATPC algorithm was disabled 2 Click Apply 3 Upon completing the test enable ATPC to resume normal operation If not enabled manually AT...

Страница 91: ...becomes the current country code The following are the available country codes Table 4 2 Country Codes Country Code Frequency Range MHz 4 9 GHz Universal 4900 5350 4 9 GHz FCC 4940 4990 4 9 GHz Japan...

Страница 92: ...required country code from the list and reset the unit to apply the new country code To select a country code IMPORTANT The selected Country Code must comply with applicable local radio regulations Th...

Страница 93: ...st The Performance Monitor menu includes the following options Link Quality Counters Page Ethernet Counters 4 10 1 Link Quality Counters Page The Link Quality On Line Display table displays read only...

Страница 94: ...rnet On Line Counters page displays RX and Tx levels for the Ethernet connection The Ethernet On Line Counters table displays a continuously updated list of the traffic counters The display is updated...

Страница 95: ...CPE 78 Product Manual Total Bytes Total Packets Rate counts are the average rate Bytes Packets per second for the last measurement interval 2 seconds Total counts are the accumulated number of Bytes P...

Страница 96: ...lect the Change Service Parameters page The Service Parameters page displays the following For IP CS Mode Service Line Count this is the number of configured services and corresponds to the number of...

Страница 97: ...Transparent is used to allow untagged packets When enabled the DSCP value of a packet arriving from the Ethernet port must be 0 otherwise it will be discarded Before forwarding to the wireless port t...

Страница 98: ...ange Service Parameters page you can change the Access VLAN as required Click Modify to apply the changes Operation Mode displays the convergence sublayer CS in the wireless access network IP CS DSCP...

Страница 99: ...nt Configuration 4 12 1 Management Parameters The Management page enables viewing the parameters related to remote over the air management of the device and to set the DSCP classifier The following pa...

Страница 100: ...and updating the parameters of the DHCP client Dhcp Client Client IP Address Network Mask Default Gateway IP Address TR069 Server IP Address By default DHCP Client is enabled IP address allocated by...

Страница 101: ...ation Logout BreezeMAX PRO 5000 CPE 84 Product Manual 4 13 Logout To log out click on the Logout menu The following window is displayed Click on the Logout button The Login page is displayed Figure 4...

Страница 102: ...e Name Choose Upload Download Action Upload Download Upload No Licences From 2 to Unlimited From 2 to 6 From 6 to Unlimited Licence lic SW File Name Yes Ethernet Port Auto Negotiation Disable Enable E...

Страница 103: ...ts of up to 3 digits each Each group range is 0 255 0 0 0 0 0 0 Yes Mobility Mode Nomadic Mobile Nomadic Yes Radio Parameters Start Rx Frequency KHz Per country code Resolution for all bands is 0 125...

Страница 104: ...hapter 4 Operation Parameters Summary BreezeMAX PRO 5000 CPE 87 Product Manual Management Configured DSCP Classifier 0 63 6 No Table 4 3 CPE Parameters Summary Parameter Range Default Run Time Updated...

Страница 105: ...A Appendix Troubleshooting...

Страница 106: ...Appendix A Troubleshooting BreezeMAX PRO 5000 CPE 89 Product Manual In This Appendix CPE Troubleshooting on page 90...

Страница 107: ...ly Unit failure Try replacing the IDU If the problem persists try replacing the IDU ODU cable If the problem persists try replacing the ODU When connected to the data equipment the Ethernet Integrity...

Страница 108: ...when Number of Supported Devices configurable from the Base station s side is set to a small number Reset the CPE to clear the table and retry the Telnet command to the unit Scanning failed and or Bas...

Страница 109: ...Glossary...

Страница 110: ...Binary Phase Shift Keying A data transfer technique BPSK transmits data using two phase modulation signals one phase representing a binary one and the other representing a binary zero The signal is d...

Страница 111: ...the DSCP field where each DSCP specifies a particular per hop behavior that is applied to the packet EAP Extensible Authentication Protocol A protocol used between a user station and an authenticator...

Страница 112: ...rs to share the network cable However only one station can use the cable at a time A variety of physical medium dependent protocols are supported IEEE 802 16 Also known as WIMAX A group of broadband w...

Страница 113: ...ost NICs are designed for a particular type of network protocol and media although some can serve multiple networks ODU Outdoor Unit OFDM Orthogonal Frequency Division Multiplexing A method for multip...

Страница 114: ...connect to the system you must enter your username and password This information is passed to a RADIUS server which checks that the information is correct and then authorizes access to the system RF...

Страница 115: ...t Protocol A set of protocols developed by the U S Department of Defense to allow communication between dissimilar networks and systems over long distances TCP IP is the de facto standard for data tra...

Страница 116: ...eneral fixed wireless use WEEE Waste Electronic and Electrical Equipment The purpose of Directive 2002 96 EC on waste electrical and electronic equipment WEEE is as a first priority the prevention of...

Отзывы: