Chapter 2 - Installation
Installing the ODU of the CPE
BreezeMAX PRO 5000 CPE
22
Product Manual
2
Insert the cable with the assembled connector through the sealing nut.
3
To expose the groove, lightly squeeze the seal. Carefully insert the cable
through the groove.
4
Insert the cable through the housing and insert the seal at the back end of the
housing.
5
Tighten the sealing nut onto the housing.
6
Stricken the gasket on the front end of the housing.
7
Connect the Ethernet cable to the IDU COM RJ-45 connector and tighten the
sealing cap.
8
Route the cable to the location selected for the indoor equipment.
9
Assemble an RJ-45 connector with a protective cover on the indoor end of the
IDU-ODU cable. Refer to the pin assignment and color codes in standard
cables described above.
2.1.6.3
Connecting the Antenna Cable (units with external antenna)
1
Mount the antenna as close as possible to the ODU.
2
Connect one end of the coaxial RF cable to the RF connector (marked
)
located at the top panel of the unit (see
).
3
Connect the other end of the RF cable to the antenna.
4
The RF connectors should be properly sealed to protect against rain and
moisture.
Figure 2-7: Inserting the IDU COM Cable into the Sealing Cap
To connect the RF cable:
Seal
Housing
Gasket
Sealing nut
Содержание BreezeMAX PRO 5000 CPE
Страница 1: ...BreezeMAX PRO 5000 CPE Product Manual Software Version 1 5 April 2010 P N 215643...
Страница 17: ...Tables BreezeMAX PRO 5000 CPE xvii Product Manual Table 4 3 CPE Parameters Summary 85...
Страница 18: ...1 Chapter Product Description...
Страница 27: ...2 Chapter Installation...
Страница 46: ...3 Chapter Commissioning...
Страница 58: ...4 Chapter Operation...
Страница 105: ...A Appendix Troubleshooting...
Страница 106: ...Appendix A Troubleshooting BreezeMAX PRO 5000 CPE 89 Product Manual In This Appendix CPE Troubleshooting on page 90...
Страница 109: ...Glossary...