background image

BreezeACCESS SU-M-900 Installation Guide 

  

 

2-6

 

Connecting the Unit 

This section describes how to connect the unit to its power supply, Ethernet 
connection and antenna, as shown in the figure below: 

 

Onboard PC

SU-M

12 VDC 2 wire

 

power cable with a

 

built-in 250 V, 3 A

 

fuse. Connect the

 

black wire to battery

 

negative, the red

 

wire to +12 and the

 

connector to the

 

SU-M's PWR port.

 

Straight 10BaseT
Ethernet cable with
standard RJ 45
connectors. Connect
to the ETH port on
the SU-M

NOTE:

Physical location of each component varies depending

 

on the vehicle.

External Antenna

Power

 

Source

 

Antenna cable, 
included with the 
Antenna installation 
kit. Connect the 
antenna to the ANT2 
connector

 

 

Figure 

 

2-1: Connection Diagram 

 

Figure 

 

2-2: SU-M-900 Front Panel 

Содержание BreezeACCESS SU-M-900

Страница 1: ...BreezeACCESS 900 SU M 900 Installation Guide June 2006 SW Version 4 5 22 P N 213919...

Страница 2: ...s trademarks or service marks of Alvarion Ltd All other names are or may be the trademarks of their respective owners Statement of Conditions The information contained in this manual is subject to cha...

Страница 3: ...IRE LIGHTNING OR OTHER HAZARD Disclaimer a The Software is sold on an AS IS basis Alvarion its affiliates or its licensors MAKE NO WARRANTIES WHATSOEVER WHETHER EXPRESS OR IMPLIED WITH RESPECT TO THE...

Страница 4: ...ATION MAINTENANCE OR USE OF ITS PRODUCTS Limitation of Liability a ALVARION SHALL NOT BE LIABLE TO THE PURCHASER OR TO ANY THIRD PARTY FOR ANY LOSS OF PROFITS LOSS OF USE INTERRUPTION OF BUSINESS OR F...

Страница 5: ...CC Radiation Hazard Warning To comply with FCC RF exposure requirements in section 1 1307 a minimum separation distance of 20cm 8 inches is required between the antenna and all persons Safety Consider...

Страница 6: ...ure that the antenna is grounded and suitable lightning protection devices are used so as to provide protection against voltage surges and static charges In any event Alvarion is not liable for any in...

Страница 7: ...ion Ltd reserves the right to alter the equipment specifications and descriptions in this publication without prior notice No part of this publication shall be deemed to be part of any contract or war...

Страница 8: ...Antenna Specifications 1 5 Installation 2 1 Packing List 2 2 Items Required for Installation 2 2 Connecting the Unit 2 6 Commissioning 3 1 Configuration Applications 3 2 Accessing the Monitor Program...

Страница 9: ...Table of Figures ix Installation Guide Table of Figures Figure 2 1 Connection Diagram 2 6 Figure 2 2 SU M 900 Front Panel 2 6...

Страница 10: ...BreezeACCESS SU M 900 Installation Guide x...

Страница 11: ...r introduces the BreezeACCESS SU M 900 system It includes the following section Introducing BreezeACCESS SU M 900 page 1 2 introduces the SU M 900 and its functionality System Specifications page 1 3...

Страница 12: ...d tested container the BreezeACCESS SU M 900 is specially designed to provide a constant network connection for law enforcement and emergency services personnel The SU M 900 8D unit can support up to...

Страница 13: ...equency Resolution 1 MHz Antenna P N 900556 5 dBi close coil linear polarized omni directional Output Power at antenna port 23 dBm typical Maximum Input Power at antenna port 20 dBm Gross Bit Rate 1 2...

Страница 14: ...Access From Wired LAN Wireless Link Management Access Protection Multilevel password Configuration of remote access direction from Ethernet only from wireless link only or from both sides Configuratio...

Страница 15: ...DC 1A max Environmental Operating Temperature 10 C 14 F to 60 C 140 F Storage Temperature 40 C 40 F to 70 C 158 F Operating Humidity 5 95 non condensing weather protected Shock Vibration According to...

Страница 16: ...BreezeACCESS SU M 900 Installation Guide 1 6...

Страница 17: ...wing sections Packing List 2 2 lists the items included with the SU M 900 Installing the SU M 900 Unit page 2 3 describes how to physically install the SU M 900 unit inside the vehicle Installing the...

Страница 18: ...ith 250 V 3 A fuse Items Required for Installation The following list comprised items required to install the SU M 900 that are not included with the installation package Installation hardware for the...

Страница 19: ...nt using four of the mounting holes in the unit as guides 2 Drill four holes in the surface using the marks you made 3 Clear all paint dirt and oil away from the area around the holes 4 If the SU M 90...

Страница 20: ...hole It is important that there be a clean metal to metal contact point between the antenna mount and the car 3 Feed cable through hole from topside and fish out where access is available on bottom s...

Страница 21: ...al to metal contact point between the antenna mount and the car 3 Assemble mount through hole from underside 4 Assemble the O ring into groove on brass nut 1 1 8 18 M mount interface nut 5 Assemble br...

Страница 22: ...Connect the black wire to battery negative the red wire to 12 and the connector to the SU M s PWR port Straight 10BaseT Ethernet cable with standard RJ 45 connectors Connect to the ETH port on the SU...

Страница 23: ...e a straight Ethernet 10Base T cable to connect a PC to the Ethernet ETH port located on the front panel of the unit Use a crossed cable to connect to a hub switch the unit can support up to 8 devices...

Страница 24: ......

Страница 25: ...2 provides an overview of how to change parameter settings Configuring Basic Parameters page 3 3 lists the basic parameters and their default values Verifying Proper Operation page 3 7 describes how...

Страница 26: ...ing the Telnet program configure the PC s IP parameters appropriately to enable connectivity with the unit The default IP address is 10 0 0 1 Using BreezeCONFIG ACCESS Connect a PC to the Ethernet por...

Страница 27: ...asic parameters and their default values Parameter Default Value Comment IP Address 10 0 0 1 Subnet Mask 255 0 0 0 Default Gateway Address 0 0 0 0 DHCP Option Disable Access to DHCP From Wlan Only ESS...

Страница 28: ...HDM Flexible Hopping Definition Parameters on page 3 10 Transmit Level 24 dBm Retain the default setting VLAN Link Type Hybrid Link VLAN ID Management 65535 Best AU Support Disable Retain the default...

Страница 29: ...o 110 NOTE The new parameters associated with the roaming scan feature are available in the Advanced Configuration Air Interface Parameters menu For details on this feature and the relevant parameters...

Страница 30: ...he Max Number of Association Authentication is reached before resetting itself the unit will report FTL Periodic association timeouts For each Association Authentication timeout the unit will report a...

Страница 31: ...ensure that the SU M 900 unit is fully operational To verify unit operation 1 Verify that the PWR LED on the SU M 900 unit is lit 2 Confirm that the PC is operational 3 Send and receive a test messag...

Страница 32: ...ime is used by the SU to perform normal traffic The interval between two consecutive Scan Dwells is set by the Beacon Interval Between Scan Dwells parameter ensuring that at least one beacon can be re...

Страница 33: ...nd 128 Kilo microseconds The range is from 1 to 10 Beacon Intervals or 0 If this parameter is set to 0 it means that the roaming feature is disabled The default is 0 Roaming Scan mode is disabled Maxi...

Страница 34: ...Bm Conversion SU in the BreezeACCESS 900 System Manual to convert values from RSSI to dBm Changes in HDM Flexible Hopping Definition Parameters Scan Entire Sub Band Option In order to increase the roa...

Отзывы: