Chapter 5 - Command Line Interface
LED Operation Mode Commands
BreezeACCESS SU-A-EZ
83
Product Manual
Example 2:
5.4.4
set ClientSta led1Target ~ led7Target
When the SNR LEDs are in threshold mode, this command sets the threshold
target value for the LED that the threshold is set for.
Syntax
set ClientSta led#Target
<
target value
>
•
target value
-
Numeric string. Range: -108...0 for RSSI, 0...100 for CRC, 0...80 for SNR,
1...8 for modulation
Command Mode
Installer, Admin
Example 1:
Example 2:
Installer# set ClientSta led5Mode eg
Installer#
Installer# set ClientSta led2Target -50
Installer#
Installer# set ClientSta led5Target 7
Installer#