TAS12-EDM & TAS12P-EDM Installation Instructions
Page 8
For Assistance: [email protected] +1 (909) 591-8431 PUD4005R1-0
Use only skilled technicians for site preparation and installation of the turnstile using Alvarado’s instructions. Refer to
the footprint and plan drawings [Figures 1 & 2] to determine the installation location and conduit requirements. See
Appendix A on page
24 for footprint and plan drawings for the Portable Base Turnstile.
• Use a level, solid concrete pad with minimum size of 4' x 4' and a minimum thickness of 4" (101.5mm).
• Do not install the turnstile on asphalt.
• There must 2" (50.8mm) of clearance between the turnstile arm and the adjacent turnstile or barrier [Figure 1].
• Stub up conduit in accordance with local electrical codes.
• Always verify the layout of the turnstile(s) before installation.
Site Preparation
Fig. 2
Fig. 1
Slab Requirements
Space & Conduit Requirements
CONDUIT HOLE
2X 5 [127]
0
37 [940]
39.2 [997]
3.8 [95]
43 [1092]
2X 4.5 [114]
6 [152]
2X 1.1 [28]
0
2X 8.4 [213]
9.5 [241]
2X 2.3 [57]
2X 3.4 [864]
4X .5 [13] THRU
ANCHORING
LOCATIONS
Adjacent Barrier or
Turnstile
2" [50.8]
OPENING
2X 34 [864]
OPENING