Supervisor 4500 User Guide
Page 34 For Assistance: [email protected] +1 (909) 591-8431
PUD4386R1-1
Fig. 17
Fig. 17
Output Terminal
Output Terminal
Block
Block
PINS 1, 7, 15, 20 - GNDX (Common Ground)
Description
Common ground terminals for access control system wiring. Only for
output terminal block use.
Purpose and Customer Use
Access control system inputs that require a ground return are
connected to these outputs.
PIN 2 - ENTACX / PIN 8 - EXTACX (Authorized Passage)
Description
An output contact is generated when a user completes an authorized
passage in the appropriate direction. This signal is generated when
a passage occurs after receipt of an ENTACC / EXTACC signal, after
receipt of an ENTOVR / EXTOVR signal, or after a passage if the
turnstile direction is in Free Passage Mode.
Purpose and Customer Use
These outputs can be used by the facility access control system to
track the number of authorized passages through the turnstile, or
compare authorized entry or exit signals issued by the facility access
control system against passages.
The following outputs are available to provide information on turnstile
operational status and activity. All output contacts are 500ms in
duration.
Outputs
Содержание SU4500
Страница 2: ...This page intentionally left blank...