PRODUCT DESCRIPTION
2.
PRODUCT DESCRIPTION
The control units of CU-TR series are designed to use as part of industrial sectional doors and
to control components of the drive system of industrial doors. Direct application is operation
control of drives TR series*:
CU-TR230
: TR-3531-230, TR-5024-230, TR-3531-230E, TR-5020-230E, TR-5024-230E
CU-TR400
: TR-5024-400, TR-10024-400, TR-13018-400, TR-5013-400E, TR-5020-400E,
TR-5024-400E, TR-10024-400E, TR-13018-400E, TR-13012-400E
The drive system
is a set of devices (electric drive, electric control unit, safety, control, light
indication, sensors) that control the door movement and ensure the safe operation of doors.
The control unit can be set to one of three operation (control) modes:
•
Manual
(manual operation mode is ON / setting
P3
–
F1
,
Table
13). The doors will move only
when the control element (button) is held. Factory settings.
•
Pulse
(manual mode is OFF). Doors movement to opening or closing, or stop of the
movement are performed by pressing the control button for a short period (pulse signal).
•
Automatic
(manual mode is OFF and
P4
automatic closing setting is ON). A one time pulse
control signal will lead to a full cycle of the doors movement: “opening — countdown of set
pause time till automatic closing — closing”.
Depending on the selected operation mode and the terms of use, the specialist determines
which control devices (key switch, remote control, etc.) and safe operation devices (safety mar-
gin, photocells, photolines, sensors) should be included into the drive system.
2.1
DELIVERY KIT
The delivery kit is shown in
Figure
1.
Y
After receiving the product, make sure that the kit is complete and that the kit components are
not visibly damaged. In case of discrepancies, contact the supplier.
2.2
SPECIFICATIONS
Table 1
FEATURE
CU-TR230
CU-TR400
Supply voltage
230 V ± 10% ~
400 V ± 10% 3 N~
Network frequency
50 Hz
Maximum drive power
1 kW
1.5 kW
Maximum power consumption in standby mode
(without additional devices)
3 W
4 W
Power supply for additional devices
12 V DC / max. 150 mA
24 V DC / max. 250 mA
Cross section of wires connected to connectors
max. 2.5 mm2
Radio control
433.92 MHz ± 0.075 MHz / dynamic code /
maximum of 32 remotes
Protection degree
IP65 (professional installation)
Operating temperature range
−20°С … +50°С
Gross weight
2.7 kg
2.9 kg
* Drives with encoder are with the designation E.
Drives with mechanical end position switches are without designation E.
Содержание CU-TR230
Страница 2: ......
Страница 44: ......
Страница 86: ......
Страница 126: ...Control units СU TR230 СU TR400 124 124 200 310 164 270 R40 90 118 244 271 350 377 2 3 ...
Страница 129: ...Control units СU TR230 СU TR400 127 127 8 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 130: ...Control units СU TR230 СU TR400 128 128 9 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 136: ...Control units СU TR230 СU TR400 134 134 5 L GND P L GND CL L O_S 16 OP L IN_S P1 F0 01 MENU S5 NO CU TR TR COM NC NO 24 ...
Страница 137: ......