The Configuration page settings are explained in the following table:
Setting
Function
OSD Hotkey
Selects which Hotkey controls the OSD function:
[Scroll Lock]
[Scroll Lock]
or [
Ctrl] [Ctrl]
. Since the Ctrl key combination may
conflict with programs running on the computers, the default is the
Scroll Lock combination. (See p. 55 for Hotkey operation.)
ID Display
Selects how the Port ID is displayed: the Port Number alone
(
PORT NUMBER
); the Port Name alone (
PORT NAME
); or the
Port Number plus the Port Name (
PORT PORT
NAME
). The default is PORT PORT NAME.
ID Duration
Determines how long a Port ID displays on the monitor after a port
change has taken place. You can choose an amount from 0 - 255
seconds. The default is 5 Seconds. 0 is Always On.
Scan Select
Selects which computers will be accessed under Auto Scan Mode
(see
, page 55). Choices are:
ALL
- All the Ports
which have been set Accessible (see
POWERED ON
- Only those Ports which have been set Accessible
and are Powered On;
QUICK VIEW
- Only those Ports which have
been set Accessible and have been selected as Quick View Ports
(see
QUICK VIEW + POWERED ON
-
Only those Ports which have been set Accessible and have been
selected as Quick View Ports and are Powered On. The default is
ALL.
Scan Duration
Determines how long the focus dwells on each port as it cycles
through the selected ports in Auto Scan Mode (see
page 55). Key in a value from 0 - 255 seconds. The default is 10
seconds; a setting of 0 disables the Scan function.
Screen Blanker
If there is no input from the console for the amount of time set with
this function, the screen is blanked. Key in a value from 1 - 30
minutes. A setting of 0 disables this function. The default is 0
(disabled).
Logout Timeout
If there is no Operator input for the amount of time set with this
function, the Operator is automatically logged out. A login is
necessary before the KN9108 / KN9116 can be accessed again.
Enter a value from 0 - 180 minutes. The default is 30 minutes. 0
disables the function.
Beeper
When set to
ON
, the beeper sounds whenever the port is switched,
when activating the Auto Scan function (see
page 55), or when an invalid entry is made on an OSD menu. The
default is ON.
Change
Password
Allows a user to change the account password. After clicking the
Change Password button, a dialog box appears. Enter the old
password. Then, enter a new password and confirm it by entering it
again. Press OK to save changes, or press Cancel to discard
changes.
kn9108_9116_2007-09.book Page 72 Friday, September 21, 2007 10:39 AM