Chapter 4. OSD Operation
29
SCAN/SKIP
MODE
Selects which computers will be accessed under Skip mode (see
, page 34), and Auto Scan mode (see
Choices are:
ALL
–
All the ports which have been set Accessible (see
QUICK VIEW
–
Only those ports which have been set Accessible and
have been selected as Quick View Ports (see
POWERED ON
–
Only those ports which have been set Accessible
and are Powered On;
QUICK VIEW + POWERED ON
–
Only those ports which have been
set Accessible and have been selected as Quick View Ports and are
Powered On. The default is ALL.
SCREEN
BLANKER
If there is no input from the console for the amount of time set with this
function, the screen is blanked. Key in a value from 1–30 minutes, then
press
[Enter]
. A setting of 0 disables this function. The default is Off.
HOTKEY
COMMAND
MODE
Enables / Disables the Hotkey function (see
page 39), in case a conflict with programs running on the computers
occurs. The default is On.
HOTKEY
This setting selects the Hotkey invocation keys (see
page 39). Choices are
[NUM LOCK] + [-]
, or
[CTRL] + [F12]
. The
default is
[NUM LOCK] + [-]
.
SET OSD
LANGUAGE
Sets the language that the OSD displays in. Choices are: English,
German, Japanese, Simplified Chinese and Traditional Chinese.The
default is English.
SET
CONSOLE
KEYBOARD
Sets the keyboard language mapping of the console keyboard. The
default is Auto. If the switch does not automatically receive language
mapping from the keyboard, it will set to English (US).
SET
LOGOUT
TIMEOUT
If there is no input from the console for the amount of time set with this
function, the operator is automatically logged out. A login is necessary
before the console can be used again.
This enables other operators to gain access to the computers when the
original operator is no longer accessing them, but has forgotten to log
out. To set the timeout value, key in a number from 1–180 minutes,
then press
[Enter]
. If the number is 0 (zero), this function is disabled.
Default is Off.
Note: T
his feature does not function if Set Login Mode is disabled.
ACTIVATE
BEEPER
Choices are
Y
(for Yes), or
N
(for No). When activated, the beeper
sounds whenever a port is changed, when activating the Auto Scan
function (see
, page 36), or an invalid entry is made on an
OSD menu. The default is On.
Setting
Function
Содержание KH1508a
Страница 1: ...KVM Switch KH1508A KH1516A User Manual www aten com...
Страница 10: ...KH1508A KH1516A User Manual x This Page Intentionally Left Blank...
Страница 16: ...KH1508A KH1516A User Manual 6 Components Front View KH1508A KH1516A 4 3 5 1 2 6 7 3 1 2 6 7 4 5...
Страница 18: ...KH1508A KH1516A User Manual 8 Rear View KH1508A KH1516A 1 2 6 4 5 3 1 2 6 4 5 3...
Страница 20: ...KH1508A KH1516A User Manual 10 This Page Intentionally Left Blank...
Страница 28: ...KH1508A KH1516A User Manual 18 Daisy Chain Installation Diagram...
Страница 32: ...KH1508A KH1516A User Manual 22 This Page Intentionally Left Blank...
Страница 48: ...KH1508A KH1516A User Manual 38 This Page Intentionally Left Blank...