Altronix VertiLine24 Series Скачать руководство пользователя страница 6

 

- 6 - 

VertilLine24 Series Installation Guide

OFF

RESET

28VAC

OFF

24VAC

28VAC

OFF

24VAC

17

18

19

20

13

14

15

16

9

10

11

12

5

6

7

8

1

2

3

4

21

22

23

24

28VAC

OFF

24VAC

28VAC

OFF

24VAC

AC POWER

Main Fuse

13-24

1

2

3

4

N P N P N P N P

5

6

7

8

N P N P N P N P

9

10

11

12

N P N P N P N P

13

14

15

16

N P N P N P N P

17

18

19

20

N P N P N P N P

21

22

23

24

N P N P N P N P

Main Fuse

1-12

(ON)

1.625"(41.3mm)

17.625" (447.7mm)

8.5" (216mm)

0.75"

(19.1mm)

19.125" (486mm)

Front

Rear

Top and Bottom

1U EIA 19” Rack Mount Chassis 

Mechanical Drawing & Dimensions 

(H x W x D)

:

1.625” x 19.125” x 8.5” (41.3mm x 486mm x 216mm)

Fig. 3

Power Switch With Built-In Circuit Breaker:

 

OFF position - Switch not illuminated. Outputs not powered.

 

RESET (ON) position - Switch illuminated. Outputs powered.

 

Circuit breaker tripped - Switch not illuminated. 

 

Power LEDs on faceplate are not illuminated. Outputs not powered.

 

To reset circuit breaker set power switch to the ON (RESET) position

 

(Fig. 3, pg. 6)

.

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user 

to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of 

sufficient magnitude to constitute an electric shock.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of impor-

tant operating and maintenance (servicing) instructions in the literature accompanying the appliance.

CAUTION:

 To reduce the risk of electric shock do not open enclosure. 

There are no user serviceable parts inside. 

Refer servicing to qualified service personnel.

Содержание VertiLine24 Series

Страница 1: ... 24 PTC protected outputs VertiLine246D 24VAC or 28VAC 14A Twenty four 24 PTC protected outputs VertiLine24 Series CCTV Rack Mount Power Supplies Models Include Rev 031808 More than just power TM Installing Company ________________ Service Rep Name ___________________________________ Address ______________________________________________ Phone ___________________ Installation Guide ...

Страница 2: ...0 3 wire grounded line cord detachable Mechanical Units can be rack wall or shelf mounted Modular 1U standard EIA 19 rack mount chassis Enclosure Dimensions H x W x D approx 1 625 x 19 125 x 8 5 41 3mm x 486mm x 216mm Twenty four 24 Output Rack Mount Configuration Reference Chart Altronix Model Number Output Voltage VAC Total Output Current Power Number of Outputs Output Protection Class 2 Rated P...

Страница 3: ...ditional camera Outputs 2 24 After wiring is completed insert terminal block into the corresponding connector and secure by tightening the screws 10 Upon completion of the wiring set illuminated master power disconnect circuit breaker to the ON RESET position Fig 3 pg 6 11 The power LEDs Green on the faceplate for Outputs 1 24 will illuminate when AC power is present Fig 1a pg 4 If any of these LE...

Страница 4: ...AC OFF 24VAC 28VAC OFF 24VAC 1b Output voltage switches Selects 24VAC or 28VAC or OFF for each output 1a LED s 1 24 Power LED indicators 1g IEC 320 Connector 115VAC 60Hz 230VAC 50 60Hz grounded line cord included Fig 1 1c Input Voltage Switch Selects 115VAC 230VAC 50 60Hz switch is located on the left side of the unit 115VAC 220VAC 1e Power Outputs 24VAC or 28VAC 1f Output Fuses Automotive blade f...

Страница 5: ...14 15 16 9 10 11 12 5 6 7 8 1 2 3 4 21 22 23 24 Main Fuse 13 24 1 2 3 4 N P N P N P N P 5 6 7 8 N P N P N P N P 9 10 11 12 N P N P N P N P 13 14 15 16 N P N P N P N P 17 18 19 20 N P N P N P N P 21 22 23 24 N P N P N P N P Main Fuse 1 12 28VAC OFF 24VAC 28VAC OFF 24VAC AC POWER Fig 2 Typical Hookup ...

Страница 6: ...uts not powered RESET ON position Switch illuminated Outputs powered Circuit breaker tripped Switch not illuminated Power LEDs on faceplate are not illuminated Outputs not powered To reset circuit breaker set power switch to the ON RESET position Fig 3 pg 6 The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGERO...

Страница 7: ...ft Remove Wall Mount Installation 1 Install mounting brackets A on the left and right side of rack chassis using two 2 flat head screws B included Fig 5a 2 Place unit at desired location and secure with mounting screws not included Fig 5b Caution It is necessary to make sure mounting screws are securely fastened to a beam when installing Fig 5 Fig 5a Fig 5b B A Fig 6 Shelf Installation 1 Position ...

Страница 8: ...Notes Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 website www altronix com e mail info altronix com Lifetime Warranty IIVertiLine24 Series K04U MEMBER ...

Отзывы: