background image

VertiLine33DV

  -  12VDC @ 8A
  -  Sixteen (16) PTC protected outputs

VertiLine33TDV

  -  12VDC @ 16A
  -  Sixteen (16) PTC protected outputs

VertiLine63DV

  -  24VDC @ 8A
  -  Sixteen (16) PTC protected outputs

VertiLine63TDV

  -  24VDC @ 16A
  -  Sixteen (16) PTC protected outputs

VertiLine 33DV/63DV Series

Rack Mount Power Supplies

Models Include:

Rev. 090810

More than just power.

TM

Installing Company:  _______________ Service Rep. Name:  __________________________________  

Address:  _____________________________________________  Phone #:  __________________

Installation Guide

Содержание VertiLine 33DV Series

Страница 1: ...ed outputs VertiLine63TDV 24VDC 16A Sixteen 16 PTC protected outputs VertiLine 33DV 63DV Series Rack Mount Power Supplies Models Include Rev 090810 More than just power TM Installing Company ________________ Service Rep Name ___________________________________ Address ______________________________________________ Phone ___________________ Installation Guide ...

Страница 2: ...ircuit breaker with manual reset IEC 320 3 wire grounded line cord detachable Removable terminal blocks with locking screw flange Mechanical Units can be rack wall or shelf mounted Modular 1U standard EIA 19 rack mount chassis Enclosure Dimensions H x W x D approx 1 625 x 19 125 x 8 5 41 3mm x 486mm x 216mm Sixteen 16 Output Rack Mount Configuration Reference Chart Altronix Model Number Output Vol...

Страница 3: ...ed master power disconnect circuit breaker to the OFF position Fig 1c pg 4 8 Connect the power output of terminals marked 1 to the power input of device Fig 1b pg 4 Repeat this step for each additional device Outputs 2 16 9 Upon completion of wiring set illuminated master power disconnect circuit breaker to the ON RESET position Fig 1c pg 4 10 The power LEDs on the faceplate for Outputs 1 8 will i...

Страница 4: ...wer disconnect circuit breaker switch OFF position Circuit breaker tripped Switch not illuminated RESET ON position Switch illuminated 1d IEC 320 Connector 220VAC 50 60Hz grounded line cord included 1e Removable Terminal Block Fig 1 VertiLine33DV VertiLine33TDV VertiLine63DV and VertiLine63TDV front 1a 1b 1c 1d 1e Removable Terminal Block ...

Страница 5: ...n Guide 5 Fig 2 Typical Application Drawing 12VDC VertiLine33DV VertiLine33TDV or 24VDC VertiLine63DV VertiLine63TDV Power Outputs to Devices 12VDC VertiLine33DV VertiLine33TDV or 24VDC VertiLine63DV VertiLine63TDV Power Outputs to Devices ...

Страница 6: ...s not powered To reset circuit breaker set power switch to the ON RESET position Fig 3 pg 6 The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral triangle is ...

Страница 7: ... Left Remove Wall Mount Installation 1 Install mounting brackets A on the left and right side of rack chassis using two 2 flat head screws B included Fig 5a 2 Place unit at desired location and secure with mounting screws not included Fig 5b Caution It is necessary to make sure mounting screws are securely fastened to a beam when installing Fig 5 Fig 5a Fig 5b B A Fig 6 Shelf Installation 1 Positi...

Страница 8: ...Notes Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 website www altronix com e mail info altronix com Lifetime Warranty IIVertiLine33DV 63DV Series K04U MEMBER ...