Overview:
Trove2SL2 accommodates various combinations of Sielox boards with or without Altronix power supplies and accessories for
access control systems.
Installation Instructions for Trove2:
1. Remove backplane from enclosure prior to mounting (do not discard hardware).
2. Mark and predrill holes in the wall to line up with the top keyholes in the enclosure. Install the upper fasteners and
screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the screws, level and
secure. Mark the position of the lower holes. Remove the enclosure. Drill the lower holes and install the fasteners.
Place the enclosure’s upper keyholes over the upper screws. Install the lower screws and make sure to tighten all screws
(Enclosure Dimensions, pg. 4).
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge.
Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side (Fig. 1, pg. 1).
Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device.
To activate alarm signal open the door of the enclosure.
4. Mount Altronix/Sielox boards to backplane, refer to pages 2-3.
Hardware:
Fig. 1
All registered trademarks are property of their respective owners.
TSL2_Rev. 110217
Nylon or Metal Standoff
5/16” Pan Head Screw
Access & Power Integration
Trove2SL2 TSL2
- Trove2 enclosure with
- Altronix/Sielox backplane only
Altronix/Sielox backplane (TSL2)
Installation Guide
Edge of
Enclosure
to Access Control
Panel or
UL Listed
Reporting
Device
Enclosure
Tamper
Switch
(provided)