T3SSK75F28

28 Door Kit with Fused Outputs 

Fully assembled kit includes:

  -  Trove3 enclosure with TSS3 Altronix/Lenel-S2 (S2 Security Platform) backplane
  -  One (1) eFlow104NB - Power Supply/Charger
  -  One (1) eFlow102NB - Power Supply/Charger
  -  Three (3) ACM8 - Fused Access Power Controllers
  -  One (1) ACM4 - Fused Access Power Controller
  -  Two (2) PD16W - Fused Power Distribution Module
  -  One (1) RSB2* - Rocker Switch Bracket with Two (2) Rocker Switches (Not evaluated by UL)

T3SSK75F28D

28 Door Kit with PTC Outputs 

Fully assembled kit includes:

  -  Trove3 enclosure with TSS3 Altronix/Lenel-S2 (S2 Security Platform) backplane
  -  One (1) eFlow104NB - Power Supply/Charger
  -  One (1) eFlow102NB - Power Supply/Charger
  -  Three (3) ACM8CB - PTC Access Power Controllers
  -  One (1) ACM4CB - PTC Access Power Controller
  -  Two (2) PD16WCB - PTC Power Distribution Module
  -  One (1) RSB2* - Rocker Switch Bracket with Two (2) Rocker Switches (Not evaluated by UL)

All components of this Trove kit are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.

Rev. T3SSK_081220

Installing Company:  _________________________ Service Rep. Name:  __________________________________________ 

Address:  _________________________________________________________  Phone #:  _________________________

All registered trademarks are property of their respective owners.

Installation Guide

More than just power.™

Access & Power Integration

Altronix/Lenel-S2 (S2 Security Platform) Kits

Models Include:

Содержание Trove T3SSK75F28

Страница 1: ...e 1 eFlow102NB Power Supply Charger Three 3 ACM8CB PTC Access Power Controllers One 1 ACM4CB PTC Access Power Controller Two 2 PD16WCB PTC Power Distribution Module One 1 RSB2 Rocker Switch Bracket with Two 2 Rocker Switches Not evaluated by UL All components of this Trove kit are UL Listed sub assemblies Please refer to the included corresponding Sub Assembly Installation Guides for further infor...

Страница 2: ... be in accordance with the National Electrical Code NFPA 70 ANSI and with all local codes and authorities having jurisdiction Product is intended for indoor use only 1 Remove backplane from enclosure Do not discard hardware 2 Mark and predrill holes in the wall to line up with the top two three keyholes in the enclosure Install two three upper fasteners and screws in the wall with the screw heads ...

Страница 3: ...r Control MAIN TRG FACP 1 2 3 4 1 2 3 4 O N O N 1 2 3 4 1 2 3 4 O N O N Altronix ACM8 CB OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 INPUT TRIGGER 10A 250V INP T RET NO C NC FACP INTERFACE Power Control M...

Страница 4: ...12 768 1mm 14 01 355 9mm 14 01 355 9mm 1 25 31 8mm 1 55 39 4mm 1 78 45 2mm 1 25 31 8mm 1 07 27 2mm 1 10 27 9mm 2 50 8mm 10 75 273 1mm 10 75 273 1mm 10 62 269 8mm 2 00 50 8mm 10 75 273 1mm 10 75 273 1mm 10 62 269 8mm 36 12 917 5mm 33 63 854 2mm Altronix is not responsible for any typographical errors 140 58th Street Brooklyn New York 11220 USA phone 718 567 8181 fax 718 567 9056 web site www altron...

Отзывы: