Altronix HubWayLDD Series Скачать руководство пользователя страница 1

Z1409

Video • Data • Power

HubWayLD8D

  -  UL Listed eight (8) Channel Active UTP
    Transceiver Hub with Integral Camera Power

HubWayLD82D

  -  UL Listed eight (8) Channel Active UTP
    Transceiver Hub with Integral Camera Power
  -  Includes eight (8) UL Listed Accessory
    HubWayAv Video Balun/Combiners

HubWayLD83D

  -  UL Listed eight (8) Channel Active UTP
    Transceiver Hub with Integral Camera Power
  -  Includes eight (8) UL Listed Accessory
    HubWayDv Video Balun/Combiners

HubWayLD16D

  -  UL Listed sixteen (16) Channel Active UTP
    Transceiver Hub with Integral Camera Power

HubWayLD162D

  -  UL Listed sixteen (16) Channel Active UTP
    Transceiver Hub with Integral Camera Power
  -  Includes sixteen (16) UL Listed Accessory
    HubWayAv Video Balun/Combiners

HubWayLD163D

  -  UL Listed sixteen (16) Channel Active UTP
    Transceiver Hub with Integral Camera Power
  -  Includes sixteen (16) UL Listed Accessory
    HubWayDv Video Balun/Combiners

HubWayLDD Series

Active UTP Transceiver Hubs
with Integral Camera Power

Models Include:

Rev. 030408

More than just power.

TM

Installing Company:  _______________ Service Rep. Name:  __________________________________  

Address:  _____________________________________________  Phone #:  __________________

Installation Guide

Содержание HubWayLDD Series

Страница 1: ...Transceiver Hub with Integral Camera Power HubWayLD162D UL Listed sixteen 16 Channel Active UTP Transceiver Hub with Integral Camera Power Includes sixteen 16 UL Listed Accessory HubWayAv Video Balun Combiners HubWayLD163D UL Listed sixteen 16 Channel Active UTP Transceiver Hub with Integral Camera Power Includes sixteen 16 UL Listed Accessory HubWayDv Video Balun Combiners HubWayLDD Series Active...

Страница 2: ... use with 12VDC cameras HubWayDvi for use with non isolated 12VDC cameras Optional HubSat4D allows transmission of up to four 4 video signals over a single CAT 5 or higher structured cable HubWayLD82D HubWayLD8D with eight 8 UL Listed Accessory HubWayAv Video Balun Combiners for 24VAC Cameras HubWayLD83D HubWayLD8D with eight 8 UL Listed Accessory HubWayDv Video Balun Combiners for 12VDC Cameras H...

Страница 3: ...e must not exceed 3 000 ft for video transmission between the HubWayLD8D LD16D and each camera routed through the HubSat4D 10 Set illuminated master power disconnect circuit breaker to the RESET ON position Fig 5 pg 7 and measure the output voltage at the power output of each Video Balun Combiner Fig 2b 2d pg 5 before powering each camera to ensure proper operation and avoid possible damage HubWay...

Страница 4: ...a transmission to PTZ s 1f BNC Connector Video outputs to head end equipment DVR 1d Output voltage switches Selects 24VAC 28VAC OFF for each output 1b Channels 1 4 Channels 5 8 Channels 9 12 Channels 13 16 CAT 5 or higher structured cable from optional HubSat4D enables video transmission from up to four 4 cameras 1i LED s 1 16 Video signal indicators 1j IEC 320 Connector 115VAC 60Hz 230VAC 50 60Hz...

Страница 5: ... Camera To BNC Connector of Camera Structured Cable from HubWay8CD or HubWay16CD Structured Cable from HubWay8CD or HubWay16CD VIDEO BALUN COMBINER HubWayDv CAT5 DATA 12VDC Wire Connectors Also Available as HubWayDvi Video Balun Combiner for non isolated 12VDC cameras Fig 2 Fig 2a Fig 2c Fig 2b Fig 2d Fig 2e HubWayAV2 Video from Camera Data to Camera Power to Camera Cat5 back to HubWay or HubSat H...

Страница 6: ...eo Balun Combiner HubWayAv Video Balun Combiner Fixed Camera Fixed Camera Max video 3000 ft PTZ Camera Video Power HubWayDv Dvi Video Balun Combiner CAT 5 24VAC 28VAC Camera Power Provided by HubSat4D Video Data Power Outdoor NEMA Rated Power Supply Outdoor PTZ Camera 115VAC Input 50 60Hz HubWayAv or HubWayDv Dvi Video Balun Combiner Monitor Rear Front 1 2 3 4 CH 1 4 CH 5 8 28VAC OFF 24VAC DATA 1 ...

Страница 7: ... Top and Bottom Fig 5 Illuminated master power disconnect circuit breaker OFF position Circuit breaker tripped Switch not illuminated RESET ON position Switch illuminated The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to consti...

Страница 8: ... screws B included Fig 7a 2 Place unit at desired location and secure with mounting screws not included Fig 7b Caution It is necessary to make sure mounting screws are securely fastened to a beam when installing Fig 7 Fig 7a Fig 7b B A Fig 8 Shelf Installation 1 Position and affix rubber pads C included at each corner on the bottom of the unit Fig 8 2 Place unit in desired location A B C Mounting ...

Отзывы: