background image

Rev. 032108

Passive UTP Transceiver Hub

with Integral Camera Power

Installation Guide

Models Include:

HubWay8CD HubWay16CD

-  UL Listed eight (8) Channel Passive UTP 

-  UL Listed sixteen (16) Channel Passive UTP

  Transceiver Hub with Integral Camera Power 

  Transceiver Hub with Integral Camera Power

HubWay82CD HubWay162CD

-  UL Listed eight (8) Channel Passive UTP 

-  UL Listed sixteen (16) Channel Passive UTP

  Transceiver Hub with Integral Camera Power 

  Transceiver Hub with Integral Camera Power

-  Includes eight (8) UL Listed Accessory   

-  Includes sixteen (16) UL Listed Accessory   

  HubWayAv Video Balun/Combiners 

  HubWayAv Video Balun/Combiners 

HubWay83CD HubWay163CD

-  UL Listed eight (8) Channel Passive UTP 

-  UL Listed sixteen (16) Channel Passive UTP

  Transceiver Hub with Integral Camera Power 

  Transceiver Hub with Integral Camera Power

-  Includes eight (8) UL Listed Accessory  

-  Includes sixteen (16) UL Listed Accessory 

  HubWayDv Video Balun/Combiners 

  HubWayDv Video Balun/Combiners

More than just power.

TM

Video • Data • Power

Содержание HubWay8CD

Страница 1: ...ransceiver Hub with Integral Camera Power Transceiver Hub with Integral Camera Power Includes eight 8 UL Listed Accessory Includes sixteen 16 UL Listed Accessory HubWayAv Video Balun Combiners HubWayAv Video Balun Combiners HubWay83CD HubWay163CD UL Listed eight 8 Channel Passive UTP UL Listed sixteen 16 Channel Passive UTP Transceiver Hub with Integral Camera Power Transceiver Hub with Integral C...

Страница 2: ...bWay16CD with sixteen 16 UL Listed Accessory HubWayAv Video Balun Combiners for 24VAC Cameras HubWay163CD HubWay16CD with sixteen 16 UL Listed Accessory HubWayDv Video Balun Combiners for 12VDC Cameras Agency Listings UL Listed for Commercial CCTV Equipment UL 2044 CUL Listed CSA Standard C22 2 No 1 04 Audio Video and Similar Equipment Data RS422 RS485 data inputs Power Individually selectable 24V...

Страница 3: ...e is required Optionally an Altronix HubSat4D Passive UTP Transceiver Hub with Integral Camera Power may be utilized Fig 4a pg 6 The combined total cable distance must not exceed 750 ft for video transmission between the HubWay8 16 and each camera routed through the HubSat4D 9 Set illuminated master power disconnect circuit breaker to the RESET ON position Fig 5 pg 7 and measure the output voltage...

Страница 4: ...be utilized for the data transmission to PTZ s 1f BNC Connector Video outputs to head end equipment DVR 1d Output voltage switches Selects 24VAC 28VAC OFF for each output 1b Channels 1 4 Channels 5 8 Channels 9 12 Channels 13 16 CAT 5 or higher structured cable from optional HubSat4D enables video transmission from up to four 4 cameras 1g IEC 320 Connector 115VAC 60Hz grounded line cord included F...

Страница 5: ...bWayAv2 24VAC 28VAC 24VAC 28VAC 24VAC 28VAC N A HubWayDv 24VAC 28VAC 12VDC 12VDC cameras Red HubWayDvi 24VAC 28VAC 12VDC electronically isolated 12VDC cameras without isolation Red Based on camera load and structured cable length VIDEO BALUN COMBINER CAT5 DATA POWER AC VIDEO HubWayAv VIDEO AC Power to Camera Data to Camera Data to Camera Green Power LED 12VDC Power to Camera Red Power LED Wire Con...

Страница 6: ... Camera HubWayDv Dvi Video Balun Combiner Video Data Power Video Data Power HubWayAv Video Balun Combiner HubWayAv Video Balun Combiner Max video 750 ft Video Power HubWayDv Dvi Video Balun Combiner CAT 5 24VAC 28VAC Camera Power Provided by HubSat4D Video Data Power Outdoor NEMA Rated Power Supply Outdoor PTZ Camera 115VAC Input 50 60Hz HubWayAv or HubWayDv Dvi Video Balun Combiner Monitor Rear F...

Страница 7: ...r tripped Switch not illuminated RESET ON position Switch illuminated The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product s enclosure that may be of sufficient magnitude to constitute an electric shock The exclamation point within an equilateral triangle is intended to alert the...

Страница 8: ...m when installing the unit vertically Rack Mount Installation 1 Remove and discard factory installed screws from both sides of rack chassis Fig 6a 2 Install mounting brackets A on the left and right side of rack chassis using the four 4 flat head screws B included Fig 6b 3 Place unit into desired EIA 19 rack position and secure with mounting screws not included Fig 6c Fig 8 Fig 7 Shelf Installatio...