background image

More than just power.

TM

Rev. 041212

Video • Data • Power

Passive UTP Transceiver Hub

with Integral Camera Power

Installation Guide

Models Include:

HubSat8DV

  -  Eight (8) Channel Passive UTP Transceiver Hub with Integral Camera Power

HubSat82DV

  -  Eight (8) Channel Passive UTP Transceiver includes eight (8) HubWayAv Video Balun/Combiners

HubSat83DV

  -  Eight (8) Channel Passive UTP Transceiver includes eight (8) HubWayDv Video Balun/Combiners

Содержание HubSat Series

Страница 1: ...stallation Guide Models Include HubSat8DV Eight 8 Channel Passive UTP Transceiver Hub with Integral Camera Power HubSat82DV Eight 8 Channel Passive UTP Transceiver includes eight 8 HubWayAv Video Balun Combiners HubSat83DV Eight 8 Channel Passive UTP Transceiver includes eight 8 HubWayDv Video Balun Combiners ...

Страница 2: ...th HubWay HubWayLD HubWayLDH UTP Transceiver Hubs pg 4 Alternate 24VAC Fixed Camera Hookup pg 5 HubSat Circuit Board pg 6 HubWayAv HubWayAv2 HubWayDv and HubWayDvi Video Balun Combiners pg 7 CAT 5 Structured Cable Wiring Color Codes pg 7 Typical Application Drawings HubSat8DV Passive UTP Transceiver Hub with Integral Camera Power pg 9 HubSat8DV Remote Accessory Module with HubWay UTP Transceiver H...

Страница 3: ...ns pg 12 Secure green wire lead to earth ground 2 Set illuminated master power disconnect circuit breaker to the OFF position Fig 3a pg 8 3 Connect unswitched AC circuit 220VAC 60Hz as follows Green branch wire ground connects to the terminal marked Line connects to the terminal marked L and Neutral connects to the terminal marked N of the Inlet Appliance Connector Fig 3 pg 8 The power LEDs Green ...

Страница 4: ...ut may be due to a blown fuse or a tripped PTC caused by a short circuit or overload condition If all of the LEDs are OFF there may be a complete loss of supply power to the HubSat8DV unit or the illuminated master power disconnect circuit breaker is in the OFF position or the primary in line fuse is blown To restore the power output for HubSat8DV 1 Switch corresponding output voltage switch to th...

Страница 5: ...tion Fig 3a pg 8 10 The power LEDs Green of the HubSat8DV will illuminate when AC power is present Fig 1e pg 6 Note If any of the power LEDs are not illuminated the cause may be due to the following a AC mains fail b Illuminated master power disconnect circuit breaker is tripped c An individual power output voltage switch is set to the OFF position Fig 1d pg 6 d A PTC is tripped due to a short cir...

Страница 6: ...for PTZ control 1g Channels 1 4 Single CAT 5 or higher structured cable out to HubWay HubWayLD or HubWayLDH enables transmission of up to four 4 video signals 1h Data CAT 5 or higher structured cable to data port on HubWay HubWayLD or HubWayLDH or head end equipment DVR 1i Channels 1 4 CAT 5 or higher structured cable to cameras Pin out configuration pg 7 PVD1 VIDEO1 VIDEO2 VIDEO3 VIDEO4 PVD2 PVD3...

Страница 7: ...ra Red Power LED Wire Connectors RJ45 Jack RJ45 Jack To BNC Connector of Camera To BNC Connector of Camera Structured Cable from HubWay8CD or HubWay16CD Structured Cable from HubWay8CD or HubWay16CD VIDEO BALUN COMBINER HubWayDv CAT5 DATA 12VDC Wire Connectors Also Available as HubWayDvi Video Balun Combiner for non isolated 12VDC cameras Fig 2 Fig 2a Fig 2c Fig 2b Fig 2d Fig 2e HubWayAV2 Video fr...

Страница 8: ... 8 HubSat8DV Input 220VAC 60Hz Fig 3a Illuminated master power disconnect circuit breaker OFF position circuit breaker tripped Switch not illuminated RESET ON position Switch illuminated Fig 3 ...

Страница 9: ...Equipment DVR RS485 Monitor Rear Front 1 2 3 4 CH 1 4 CH 5 8 28VAC OFF 24VAC DATA 1 8 5 6 7 8 PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE AC POWER GAIN 8 7 6 5 4 3 2 1 Video Coax Power Video Coax Power 24VAC Fixed Camera Video Coax Power 24VAC 28VAC Camera Power Provided by HubSat8DV 115VAC Input 50 60Hz 24VAC Fixed Camera Video Power HubWayDv...

Страница 10: ... 10 HubSat8DV Notes ...

Страница 11: ...HubSat8DV 11 Notes ...

Страница 12: ...t within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance CAUTION To reduce the risk of electric shock do not open enclosure There are no user serviceable parts inside Refer servicing to qualified service personnel Enclosure Dimensions H x W x D approximate 13 5 x 13 x 3 ...

Отзывы: