background image

Overview:

Altronix ALTV615DC8ULCB CCTV Power Supply is designed with eight (8) individually PTC protected power-limited, 

Class 2 Rated outputs for powering CCTV cameras and other video accessories. It provides 6VDC-15VDC distributed via 

eight (8) PTC outputs with a total of up to 4A continuous supply current.

Specifications:

Agency Listings:

•  UL Listed for Commercial Closed-Circuit Television Equipment (UL 2044).

•  CUL Listed - CSA Standard C22.2 No.1-98, Audio, Video and Similar Equipment.

Input:

•  Input 115VAC 50/60 Hz, 0.9A.

Output:

•  6VDC-15VDC adjustable output.

•  Eight (8) individually PTC protected, Class 2 Rated

  power-limited outputs.

•  4A total continuous supply current. 

•  Filtered and electronically regulated outputs.

PTC Ratings:

•  Output PTCs are rated at 2.5A/250VAC (Fig. 1).

Visual Indicators:

•  AC input and DC output LED indicators.

Additional Features:

•  Spare fuses included.

•  Unit maintains camera synchronization.

•   Ease of installation saves time and eliminates costly labor.

Enclosure Dimensions 

(H x W x D approx.)

:

13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm).

Note: For a model with factory installed 3-wire line cord 

add suffix “3” (e.g.  ALTV615DC8ULCB3) and disregard 

paragraph 2 in Installation Instructions.

Installation Instructions:

1.  Mount ALTV615DC8ULCB in desired location.

2.  Connect green lead to earth ground. Connect AC (115VAC 50/60 Hz) to the black and white flying leads of the

 transformer 

(Fig. 1). Use knockout adjacent to the transformer. 0.25” spacing must be provided between AC input 

 

wiring and all other circuits. 

3.  Adjust output voltage using trimpot on the board prior to connecting CCTV devices.

4.  Measure output voltage before connecting devices. This helps avoiding potential damage.

 

Terminals marked [1P-8P] are positive (+) and terminals marked [1N-8N] are negative.

 

CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting the    

 

output voltage.

5.

  Connect each DC CCTV cameras to the terminal pairs marked [1P-1N] through [8P-8N] on PD8CB board (Fig. 1), 

 

carefully observing correct polarity.

6.  Green LED will illuminate when when unit is powered.

7.  Upon completion of the wiring secure enclosure door with screws (supplied).

 

Keep power-limited circuits (outputs 1 through 8) away from non power-limited. 0.25” space must be provided.  

 

Use separate knockouts.

 

Caution: Equipment to be installed/serviced by authorized/trained personnel only. 

 

Shut branch circuit power before installing/servicing equipment.

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This 
installation should be made by qualified service personnel and should conform to NEC and all local codes. 

ALTV615DC8ULCB

CCTV Camera and Accessory Power Supply

Door

Green

Lead

Wire 

Strap

(from

Enclosure

to Door)

XFMR

Black

Lead

White

Lead

115VAC Input

50/60 Hz,

0.9A

non power- 

limited

N

COMMON   POWER   OUTPUTS

P

FUSED    POWER    OUTPUTS

8

D1

INPUT

R1

LED

F1

F2

F3

F4

F5

F6

F7

F8

+   DC    

-

-  BAT  +

AC

AC

DC

AC

V

oltage

Adjustment

Class 2 Not Wet/

Class 3 Wet

Use separate 

knockouts for

power-limited

circuits.

Fig. 1

Отзывы: