background image

Auto Ranging True RMS Pro Digital Multimeter

Instruction Manual

Model: Q 1073A

• True RMS AC measurement • 6000 count reverse backlit LCD • Autoranging 

• Frequency counter to 10MHz • Capacitance measurement • Fused 10A input 

• Temperature mode (°C/°F) • Test socket LED lights • Continuity and diode test 

• Internal rechargeable lithium battery • Range hold & relative mode • Data hold 

• Wireless USB charging adaptor • Cat III 1000V/Cat IV 600V

Features

Содержание 769

Страница 1: ...nt reverse backlit LCD Autoranging Frequency counter to 10MHz Capacitance measurement Fused 10A input Temperature mode C F Test socket LED lights Continuity and diode test Internal rechargeable lithiu...

Страница 2: ...electrical sources Live wire detection Input Jack Indicators to remind users to plug in the correct jacks Frequency Measurement and Temperature Measurement Vertical Alignment Display which provide la...

Страница 3: ...suring DC Current 9 D Measuring AC Current 10 E Measuring Resistance 11 F Continuity Test 12 G Diode Test 13 H Measuring Temperature 14 I Measuring Frequency 14 J Measuring Capacitance 15 K Detecting...

Страница 4: ...of the lowest rated individual component of a Product probe or accessory Avoid to use the equipment in the environment with strong magnetic fields strong electrostatic fields and strong RF fields Com...

Страница 5: ...nown voltage Remove the batteries if the equipment planned to be stored for long period or if stored in temperatures above 50 C If the batteries are not removed battery leakage can damage the Product...

Страница 6: ...ations such as distribution panels feeders and short branch circuits and lighting systems in large buildings CAT IV IEC Overvoltage Category IV CAT IV equipment is designed to protect against transien...

Страница 7: ...Compartmen QGXFWLYH KDUJLQJ 3RVLWLRQ NCV Sensor Flashlight Holster Display KDUJLQJ QGLFDWRUV 3XVK XWWRQV CHARGER STRUCTURE 1 USB port 2 Indicator Error is happened 3 Indicator Charging DISPLAY 1 2 3...

Страница 8: ...m Megaohm Hz kHz MHz Hertz unit of frequency Kilohertz Megahertz F nF F mF Farad unit of capacitance Nanofarad Microfarad Millifarad 6 ain display digits input is out of range Meter is ready for NCV d...

Страница 9: ...e relative mode Remark REL will be displayed when relative mode is on The measured value will be stored when relative mode is switch on Display of relative mode Actual measuring value stored value At...

Страница 10: ...ction between the testing leads and the circuit under test and remove testing leads away from the input terminals of the Meter after measurement Tips The Meter have input jack indicators to advise the...

Страница 11: ...nown voltage befre using the instrument on an unknown circuit To avoid electric shock fire personal injury or damages to the Meter from electric shock please do not attempt to measure voltages higher...

Страница 12: ...ging C MEASURING DC CURRENT Warning If the fuse burns out during measurement the Meter may be damaged or the operator himsel f may be hurt To avoid possible damage to the Meter or to the equipment und...

Страница 13: ...old down the same button to return to auto ranging D MEASURING AC CURRENT Warning If the fuse burns out during measurement the Meter may be damaged or the operator himsel f may be hurt To avoid possib...

Страница 14: ...to AC mode 5 Open the circuit path to be tested and connect the testleads to the break of the circuit 6 The measured value shows on the display 7 If needed press to switch to manual ranging press agai...

Страница 15: ...ch the probe tips together and read the resistance of the leads If necessary you can use the relative REL mode to automatically subtract this value The measured value of a resistor in a circuit is oft...

Страница 16: ...h 60V DC or 30V rms AC Use the diode test to check diodes transistors and other semiconductor devices The diode test sends a current through the semicondutor junction then measure the voltage drop acr...

Страница 17: ...C F range 3 Press to switch to select C mode press one more to switch to F mode 4 Connect the testleads across with the object being measured 5 The measured value shows on the display Note The include...

Страница 18: ...e the dc voltage function to confirm that the capacitor is discharged To ensure accuracy the Meter inside is discharged against the tested capacitor This process will be quite slow Set up to measure C...

Страница 19: ...V Live range 3 Insert the red probe to the AC power socket 4 or will be displayed which indicate power is present More number of means the power is more strong L NON CONTACT VOLTAGE DETECTION Warning...

Страница 20: ...nd the number of will also increase when higher voltage is detected M RELATIVE MODE Selecting relative mode causes the Meter to zero the display and store the present reading as the reference for subs...

Страница 21: ...UT JACK INDICATOR Build in LED indicators surrounding the input jacks corresponding to the function selected will be automatically switched on to advise users to plug in the testleads SLEEP MODE The e...

Страница 22: ...1 year after calibration at operating temperatures of 23 C 5 C with relative humidity 75 Accuracy specifications take the form of of Reading Counts Function Range Resolution Accuracy of Reading Count...

Страница 23: ...10A 0 01A 3 5 10A 1000V fuse Remarks Display true RMS value Frequency Response Resistance 600 0 1 0 8 5 1000V 6k 1 60k 10 600k 100 6M 1k 60M 10k 1 5 5 Remarks Open circuit voltage approximate Continui...

Страница 24: ...1MHz 0 001MHz 10MHz 0 01MHz Sensitivity 1kHz 200mVp p 1kHz 3Vp p Capacitance 6nF 0 001nF 5 5 1000V 60nF 0 01nF 4 5 600nF 0 1nF 6 F 0 001 F 60 F 0 01 F 600 F 0 1 F 6mF 0 001mF 5 5 60mF 0 01mF MAINTENA...

Страница 25: ...ely by using the charger provided and connect as following figure if the battery indicator is on Set up to charge REPLACE FUSES Warning To avoid electrical shock or arc blast or personal injury or dam...

Страница 26: ...g the equipment NEVER submerge them in water DO NOT use abrasive cleaners they will damage the case Wipe the case with a damp cloth and mild detergent Do not use abrasives or solvents Dirt or moisture...