STEREO POWER
AMPLIFIER
LTO
R
www.altoproaudio.com
Version 1.0 April 2005
English
User's Manual
MISTRAL6000
Страница 1: ...STEREO POWER AMPLIFIER LTO R www altoproaudio com Version 1 0 April 2005 English User s Manual MISTRAL6000 ...
Страница 2: ... flame sources such as lighted candles should be placed on the apparatus IMPORTANT SAFETY INSTRUCTIONS Read these instructions Heed all warnings Follow all instructions Keep these instructions Only use attachments accessories specified by the manu facturer Power Cord and Plug Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider tha...
Страница 3: ...mments ur job we d like to share with you our work and our dreams paying attention to your suggestions Following this idea we create our products and we will create the new ones From our side we guarantee you and we will guarantee you also in future the best quality and the best fruits of our continuous researches and the best prices Our LTO MISTRAL6000 Stereo Power Amplifier is the result of many...
Страница 4: ...TABLE OF CONTENTS 1 INTRODUCTION 4 2 FEATURES 4 3 CONTROL ELEMENTS 5 3 1 The Front Panel 3 2 The Rear Panel 4 APPLICATION 8 4 1 Stereo Mode 5 TECHNICAL SPECIFICATIONS 11 6 WARRANTY 12 3 4 2 Bridge Mode ...
Страница 5: ...g conditions An automatic speed fan matches cooling capacity with heat requirements The amplifier frame contains all solid state circuitry using complementary silicon output devices The amplifier is supplied with a single moulded AC cord having an appropriate AC plug for the intended operating voltage The amplifier employs forced air cooling with a variable speed fan for minimum acoustic noise Air...
Страница 6: ...it is in heat protection no signal output at the time and over heat inside the unit the temperature the surface temperature of power transistor is 110 must be lowered through better ventilation and decrease the signal level etc After the temperature dropped the protection stop and meanwhile the Led turning off with the unit recover normal work Power Led This Led lights up when the unit is powered ...
Страница 7: ...ower cord Manual Reset Pushing Button This switch works as fuse for protecting the unit from damage When the unit is overloaded or the temperature inside the unit is too high this pushing button will spring up and break the power supply The power supply will be restored with pushing this switch down again Output Connector These connectors have two kinds Binding post and Neutrik connector You can c...
Страница 8: ...MODE BRIDGE STEREO CH1 OUTPUT1 OUTPUT1 OUTPUT2 OUTPUT2 POWER OUTPUTS POWER OUTPUTS CH1 1 1 POS NEG CH2 BRIDGE MONO BRIDGE MONO CH2 2 2 POS NEG BRIDGE BRIDGE 1 2 POS NEG CH2 1 1 POS NEG INPUT INPUT TIP PIN 2 TIP PIN 2 RING PIN 3 RING PIN 3 SLEEVE PIN 1 SLEEVE PIN 1 TIP PIN 2 TIP PIN 2 RING PIN 3 RING PIN 3 SLEEVE PIN 1 SLEEVE PIN 1 INPUT BREAKER INPUT 1 2 3 2 1 3 NEW TIDE 2 1 3 NEW TIDE 1 3 2 CH1 B...
Страница 9: ...2 2 2 POS NEG BRIDGE BRIDGE 1 2 POS NEG CH2 1 1 POS NEG INPUT INPUT TIP PIN 2 TIP PIN 2 RING PIN 3 RING PIN 3 SLEEVE PIN 1 SLEEVE PIN 1 TIP PIN 2 TIP PIN 2 RING PIN 3 RING PIN 3 SLEEVE PIN 1 SLEEVE PIN 1 INPUT BREAKER INPUT 1 2 3 2 1 3 NEW TIDE 2 1 3 NEW TIDE 1 3 2 CH1 BALANCED INPUT BALANCED INPUT PARALLEL OUTPUT PARALLEL OUTPUT LIMITER OFF ON CH2 BALANCED INPUT BALANCED INPUT PARALLEL OUTPUT PAR...
Страница 10: ...ND INPUT Input Connector Balanced MODE Release this button Channel 2 Channel 1 1 2 3 GND INPUT Input Connector Balanced MODE Release this button Channel 2 Channel 1 Channel 1 Channel 1 CH1 BALANCED INPUT BALANCED INPUT PARALLEL OUTPUT PARALLEL OUTPUT LIMITER OFF ON CH2 BALANCED INPUT BALANCED INPUT PARALLEL OUTPUT PARALLEL OUTPUT MODE BRIDGE STEREO CH1 OUTPUT1 OUTPUT2 POWER OUTPUTS POWER OUTPUTS C...
Страница 11: ...UTPUT2 POWER OUTPUTS POWER OUTPUTS CH1 1 1 POS NEG CH2 BRIDGE MONO BRIDGE MONO CH2 2 2 POS NEG BRIDGE 1 2 POS NEG CH2 1 1 POS NEG INPUT INPUT TIP PIN 2 TIP PIN 2 RING PIN 3 RING PIN 3 SLEEVE PIN 1 SLEEVE PIN 1 TIP PIN 2 TIP PIN 2 RING PIN 3 RING PIN 3 SLEEVE PIN 1 SLEEVE PIN 1 INPUT BREAKER INPUT 1 2 3 2 1 3 NEW TIDE 2 1 3 NEW TIDE 1 3 2 CH1 BALANCED INPUT BALANCED INPUT PARALLEL OUTPUT PARALLEL O...
Страница 12: ... 10K ohms unbalanced 20K ohms balanced 56 36dB FRONT AC SWITCH CH1 CH2 GAIN KNOBS Continuously variable speed fan rear to front air flow On off muting DC fault load grounding relay Internal fault fuses 200 240 100 120 Vac 50 60Hz 19 48 3 cm rack mounting 5 2 13 3 cm tall 3 rack spaces 17 8 45 3 cm deep rack mounting to rear support ears 26 47Kg 1070W 1500W 3000W PRELIMINART Indicators 1 per channe...
Страница 13: ...TO of 1 year from the purchase date if you have completed the Warranty Registration Card in time 3 3 During the warranty service may repair or replace this product at its own option at no charge to you for LTO parts or for labor in accordance with the right side of this limited warranty 3 4 This warranty does not apply to the damages to this product that occurred as the following conditions Normal...
Страница 14: ... com Tel 886 4 22313737 email alto altoproaudio com Fax 886 4 22346757 c All rights reserved to ALTO All features and content might be changed without prior notice Any photocopy translation or reproduction of part of this manual without written permission is forbidden Copyright 2005 SEIKAKU GROUP SEIKAKU TECHNICAL GROUP LIMITED ...