AS-H40Y - 12kWAS-H50Y - 15kW AS-H60Y - 18kW
ALTO
Heat Pump installation manual
F1-F7
Страница 1: ...AS H40Y 12kW AS H50Y 15kW AS H60Y 18kW ALTOHeat Pump installation manual F1 F7 ...
Страница 2: ...onnect heater to an electrical supply using a 13 amp plug When cleaning the heater unit switch off power supply Do not operate electrical switches with wet hands Repair or relocation should be carried out by a specialist contractor INDEX Page 4 Installation and Siting Page 5 Plumbing Page 9 Electrical Connection Circuit Diagram Page 10 Control Panel Functions F1 F7 Page 13 Refrigerant Flow Meter P...
Страница 3: ...HEAT PUMP AS H40Y 12kW 2 ...
Страница 4: ...3 HEAT PUMP AS H50Y 15kW AS H60 18kW ...
Страница 5: ...ease Note the heat pump collects condensation from the evaporator fins and will continually discharge small amounts of condensate water out of the base of the unit via a drain tube Therefore it is recommended that the drain tube is directed to an area with adequate drainage Make sure that heat pump remains free of any obstructions foliage etc A minimum clearance is required around heater unit plea...
Страница 6: ...applicable for stainless steel copper heat exchangers Standard unit If your pool has an automatic chemical dosing appliance the heat pump should be installed prior to the dosing system See applicable drawings 1 4 on pages 7 8 2 x1 5 Female Threaded Socket Unions Required FLOW SWITCH Optional Alto heat pumps have the option of installing a flow switch A flow switch will deactivate the heater if the...
Страница 7: ...WITCH INSTALLATION GUIDE optional ANTI VIBRATION PADS AND DRAIN TUBE X 4 ANTI VIBRATION PADS PLASTIC Install on underside of heater It is recommended that Stainless Steel screws plugs are used when securing to floor Installing anti vibration feet will also help prevent corrsion to the base of the heat pump 1 X DRAIN VALVE RUBBER 1 X 2m FLEXIBLE DRAINAGE TUBE Insert drain valve into drainage hole l...
Страница 8: ...lumbing layout when incorporating Solar Heating If an increased flow rate is required instal a booster pump as per drw 4 below Ball Valve BACKWASH FILTER FILTER Pool Non Return Valve Back Up Heater if required PUMP Solar Heating 3 Way Valve Install a plumbing bypass for running filtration heat pump at night Non Return Valve Position for optional Erosion Feeder Condensate Water to waste Female Thre...
Страница 9: ...ystem is 3000 Litres 660 Gallons imperial per hour Ball Valve BACKWASH FILTER FILTER Pool Position for optional Erosion Feeder Non Return Valve Back Up Heater if required Condensate Water to waste PUMP Female Threaded Socket Union Ball Valve BOOSTER PUMP Solar Heating 3 Way Valve Install a plumbing bypass for running filtration heat pump at night Non Return Valve Non Return Valve Drw 3 Recommended...
Страница 10: ...tage must be available at the heat pump whilst running A 40 AMP 2 Pole Contactor is required to interlock heat pump and circulation pump i e heat pump only functions when pool circulation pump is running A flow switch provided optional see page 5 can also be installed as an extra precaution in the event that there is a loss of water flow i e circulation pump deprimes NOTE PLEASE CHECK CONTINUITY O...
Страница 11: ...re ie 10 H 10 C 2 On OFF button to turn heater on and off 3 The set button is used to set the F1 6 functions ie water temperature defrosting cycle and defrosting time etc see pages 11 12 PLEASE READ THE CONTROL FUNCTIONS CAREFULLY AND MAKE THE NECESSARY ADJUSTMENTS BEFORE USING YOUR HEATER CONTROL PANEL FUNCTIONS 1 3 10 40 H 2 10 ...
Страница 12: ... temperature Eg If current pool water temperature is 20 C F1 has been set to 02 heating mode when the temperature reaches 20 C the heater will stop and restart when the water temperature is below 18 C When the SET button is pressed for the third time the display panel will display F3 the defrosting time The recommended setting is 5 minutes To adjust setting YOU MUST PRESS THE ON OFF BUTTON FIRST U...
Страница 13: ...tandard This function is designed for saving energy EC Heat pump will stop working at an ambient temperature of 5 C and will automatically restart when the ambient temperature rises above 10 C Example When the heat pump is set in Economy mode the unit will stop working during the night when temperature drops below 5 C and will restart automatically when the temperature rises throughout the day ST ...
Страница 14: ...ent water flow Prior to any adjustments make sure your filter is clean by using the backwashing and rinse procedure refer to your pool hand book for guidance Check there are no obstructions in the suction lines i e Main Drain or Skimmer s If you are unable to increase the flow rate please contact your pool dealer as you may need to increase the size of the filtration pump or there is a lack of gas...
Страница 15: ...s a lack of water flow Backwash filter and check suction lines Skimmer s Main Drain s for obstruction E4 Indicates high water refrigerant pressure High limit pressure switch has activated and turned off power supply IF THE HEATER STOPS WORKING ONE OF THE FOUR ERRORS WILL BE DISPLAYED THE FAILURE LIGHT WILL BE ON AND THE RELEVANT CODE WILL START TO FLASH CONTROL PANEL FUNCTION ERROR DISPLAY 1 4 14 ...
Страница 16: ...tly reduce pool heating loss The use of a solar or thermal blanket will also help extend your pool season What is the minimum ambient operating temperature The Alto Water Heat Pump will actually operate down to an ambient air temperature of 0 C but with minimal heat output Therefore we recommend that the minimum operating temperature should be 5 C Other conditions such as wind shade and physical l...
Страница 17: ...g device Winterising Procedure 1 Switch off electric supply to heat pump 2 Turn off circulation pump 3 Drain water from heat pump by disconnecting pipework to and from heat pump Ensure Heat Pump is completely drained 4 Flush through water circuit in heat pump using clean tap water i e a hose into inlet connection run for 10 minutes minimum 5 Drain completely fit plastic bags secured by elastic ban...
Страница 18: ... 2 All repairs replacements must be carried out by an authorised service agent appointed by Paramount Pools 3 3 This warranty extends only to the original consumer who purchased the Alto Heat Pump 3 4 The warranty terminates upon the transfer of ownership or if the heat pump is relocated save with the written permission of Paramount Pools 3 5 The warranty is only applicable to installations in Eng...
Страница 19: ...uction in the skimmer Is there any obstruction in the pump basket Is the water at the correct operational level Is the filter pump working Is the filter operating pressure correct Does the filter require backwashing Have you checked the diagnostic control panel If the fault can not be diagnosed over the phone then your pool dealer will contact Paramount Pool Products UK Importer who will arrange a...
Страница 20: ...xD mm 540 835 540 630 770 710 630 770 710 Gross Weight Kg 70 84 110 ALTOHeat Pumps SPECIFICATION USEFUL CONVERSIONS 1 000 British Thermal Units BTU 10 000 BTU 1 UK Horsepower 0 293 kilowatt hour 1 therm 0 7457 kilowatt Cubic Yards to Cubic Metres Cubic Metres to Cubic Yards Cubic Metres to Gallons Gallons to Cubic Metres Gallons to Litres Litres to Gallons multiply by multiply by multiply by divid...