background image

U N PA C K I N G   a n d   S E T - U P

Alto-Shaam display cabinets have been
thoroughly tested, checked for calibra-
tion, and inspected to insure only the
highest quality cabinet is provided.
When you receive your cabinet, check
for any possible shipping damage and

report it at once to the delivering carrier.  

See

Transportation Damage and Claims 

section located in this manual.

The cabinet, complete with unattached items and

accessories, may be delivered in one or more packages.
Check to ensure that all the following items have been
received as standard with each unit.

2:  Chrome Plated Side Racks

3:  Chrome Plated Wire Shelves

2:  40 Watt Appliance Bulbs

Save all the information and instructions packed

inside the cabinet.  Complete and return the warranty
card to the factory as soon as possible to assure
prompt service in the event of a warranty parts and
labor claim.

NOTE:

All claims for warranty must include the full model

number and serial number of the cabinet.

ELECTRICAL INSTALLATION

An identification tag is permanently mounted on the
cabinet.

Plug the cabinet into a properly grounded receptacle
ONLY, remembering to position the unit so that the
cord is easily accessible in an emergency.

A proper outlet configuration or permanent wiring for
this model must be installed by a licensed electrician in
accordance with applicable, local electrical codes.

HEATING CHARACTERISTICS

The cabinet is equipped with a special, low-heat-density,
heating cable.  Through the Halo Heat concept, the
heating cable is mounted against the walls of the
warming compartment to provide an evenly applied heat
source controlled by a thermostat.  The design and oper-
ational characteristics of the cabinet eliminate the need
for a moisture pan or a heat circulating fan.  Through
even heat application, the quality of food is maintained
for as much as several hours.

E Q U I P M E N T   S TA R T U P

Before operating the cabinet, clean both the interior
and exterior of the unit with a damp cloth and mild
soap solution.  Rinse carefully.  A standard commercial
glass cleaner can be used on all glass.  Install the
optional casters or equipment legs before operating the
cabinet.  Clean and install the cabinet side racks, and
wire shelves.

The cleanliness and appearance of this unit will
contribute considerably to operating efficiency
and savory, appetizing food.  Good equipment that is kept
clean works better and lasts longer.

THOROUGHLY CLEAN THE UNIT DAILY

1.

Turn lights and adjustable thermostat(s) to the “OFF” 
position, and disconnect unit from power source.  

2.

Remove, cover, and store food under refrigeration.

3.

Clean the interior metal surfaces of the cabinet with a
damp cloth and any good alkaline or alkaline
chlorinated based commercial detergent or
grease solvent at the recommended strength.
Use a plastic scouring pad or oven cleaner for
difficult areas.  Avoid the use of abrasive
cleaning compounds, chloride based cleaners,
or cleaners containing quaternary salts.  Rinse
carefully to remove all residue and wipe dry.

NOTE:  Never use hydrochloric acid (muriatic acid) on 

stainless steel.

4.

Clean the glass with a window cleaner.

5.

To help maintain the protective film coating on polished
stainless steel, clean the exterior of the unit with a cleaner
recommended for stainless steel surfaces.  Spray the
cleaning agent on a clean cloth and wipe with the grain of
the stainless steel.

Always follow appropriate state or local health (hygiene) 

regulations regarding all applicable cleaning and sanita-
tion requirements for equipment.

PATENT NOS.

3521030
4595247

®

—   D I S P L AY   C A B I N E T S

®

Ensure power source 

matches voltage stamped 

on unit nameplate.

#828 Operation & Care Manual - 1.

At no time should the inside or outside 
of the cabinet be washed down, flooded with
water or liquid solution.  Do not use water jet to
clean.  NEVER STEAM CLEAN.  Severe damage
or electrical hazard could result, voiding
the warranty.

CARE AND CLEANING

Содержание 750-GDU/MET

Страница 1: ...744 U S A CANADA 262 251 1907 INTERNATIONAL www alto shaam com W 1 6 4 N 9 2 2 1 W a t e r S t r e e t P O Box 450 Menomonee Falls Wisconsin 53052 0450 U S A COOK HOLD SERVE SYSTEMS LIGHTED DISPLAY CABINETS HOT FOOD Models 750 GDU 750 GDU PT 750 GDU MET 750 GDU MET PT 750 GDU PT control side on optional casters 750 GDU MET multiple timers control side ...

Страница 2: ...urs EQUIPMENT STARTUP Before operating the cabinet clean both the interior and exterior of the unit with a damp cloth and mild soap solution Rinse carefully A standard commercial glass cleaner can be used on all glass Install the optional casters or equipment legs before operating the cabinet Clean and install the cabinet side racks and wire shelves The cleanliness and appearance of this unit will...

Страница 3: ...th MULTIPLE TIMERS 1 SWITCH POWER ON The timers will beep and the temperature display will flash momentarily The unit will begin preheating to the last set holding temperature The temperature display will indicate the actual cabinet temperature 2 SET THE HOLDING TEMPERATURE A Press and release the temperature set button The previously set holding temperature will be displayed for 3 seconds The set...

Страница 4: ...the moisture content of the product product density volume and proper serving temperatures Safe holding temperatures must also be correlated with palatability in determining the length of holding time for a specific product Halo Heat maintains the maximum amount of product mois ture content without the addition of water water vapor or steam Maintaining maximum natural product moisture preserves th...

Страница 5: ...in the thermostat dial shaft With the shaft held stationary a minute clockwise motion of the calibration screw appreciably lowers the thermostat setting A reverse or counter clockwise motion appreciably raises the thermostat setting After achieving the desired cycling of the thermostat the calibration screw must be sealed Place a few drops of enamel sealant directly on the calibration screw RED NA...

Страница 6: ...ns at the thermostat and terminal block If neces sary re secure the faulty connections Energize system after the above steps have been completed If control still reads CCC call service technician Check power source Check and replace if necessary Check line voltage for 24V across pins 6 and 7 on the power supply board Replace control Replace relay Replace element Detach the sensor from the terminal...

Страница 7: ...2 TOP MOUNTING SCREWS 2 SC 2425 3 CASTER BRACKET 2 4974 4 CASTER BRACKET MOUNTING SCREWS 8 SC 2425 5 CORD 125V 1 CD 33367 CORD 230V 1 CD 3922 BUSHING 1 BU 3011 6 CASING BOTTOM 1 14523 CASING RIGHT HAND 1 14332 CASING LEFT HAND 1 14333 7 CASING MOUNTING SCREWS 6 SC 2425 8 INSULATION 25 x 120 635mm x 3048mm 1 IN 22364 9 CABLE CONNECTION HARDWARE 10 HEATING CABLE Length 144 43891mm 1 CB 3045 11 THERM...

Страница 8: ... 3973 230V ONLY 1 FA 3974 MOUNTING SCREWS 4 SC 2661 28 INSULATION 25 X 120 635mm x 3048mm 1 IN 22364 29 HEATING CABLE LENGTH 144 1 CB 3045 30 REAR GLASS ASSEMBLY 1 4971 SERVICE VIEW PARTS LIST 750 GDU MET PT PASS THRU 5 20 03 QUANTITY A S PART DESCRIPTION PER UNIT NUMBER 1 TOP ASSEMBLY 1 14254 2 TOP MOUNTING SCREWS 4 SC 2425 3 BULB NOT SHOWN 6 LP 33268 4 BULB ASSEMBLY 6 LP 33267 5 TRANSFORMER 1 TN...

Страница 9: ... 828 Operation Care Manual 8 ...

Страница 10: ... 828 Operation Care Manual 9 ...

Страница 11: ... 828 Operation Care Manual 10 ...

Страница 12: ... 828 Operation Care Manual 11 ...

Страница 13: ... 828 Operation Care Manual 12 ...

Страница 14: ... 828 Operation Care Manual 13 ...

Страница 15: ... 828 Operation Care Manual 14 ...

Страница 16: ...chever occurs first Exceptions to the one year part warranty period are as listed A Halo Heat cook hold ovens include a five 5 year parts warranty on the heating element Labor will be covered under the terms of the standard warranty period of one 1 year or fifteen 15 months B Alto Shaam Quickchillers include a five 5 year parts warranty on the refrigeration compressor Labor will be covered under t...

Отзывы: