Altinex MT319-401 Скачать руководство пользователя страница 8

MT319-401 

User’s Guide

 

400-0698-001 

 

 
 
 
 
 
 

 

Telnet Commands 

– AV Network 

TELNET connections for control/configuration commands can 
only be made on port 23.  All commands and feedback are in 
the format open bracket ‘[‘ followed by text and end in a close 
bracket ‘]’ without carriage returns. The close bracket ‘]’ is the 
end of the command. 

Each Tx/Rx unit must respond to each command. If a 
command requests information, the data is considered the 
feedback. All other commands must return either [ ] or [ER]. An 
open and close bracket indicates the command was executed 
successfully. An [ER] indicates a bad, failed, or unrecognized 
command. 

24. 

[SET]

 

This command is used to configure the Tx unit for use on 
the AV network. Each field is separated by a space. 
Changes do not take effect until the unit is reset or the 
power is cycled. 

Command Format:  [SET address mask gateway vid] 

Address 

###.###.###.### 

Mask 

###.###.###.### 

Gateway 

###.###.###.### 

Group 

Tx units 1~64 
Rx units 1~180 

Example: 

[SET 192.168.1.110 255.255.0.0 192.168.1.0 01] 

Returns [ ] upon execution. After a reset or power cycle, the 
unit can be identified as address 192.168.1.110 with group 
number 1. 

25. 

[SFT]

 

This command tells the Tx to execute a soft reset after 
which the new IP, mask, and gateway are active. There is 
no feedback from this command, it just executes. 

Command Format:  [SFT] 

Example: 

[SFT] 

This is the equivalent of cycling the power. If network 
changes were made using the [SET] command, the new 
changes take effect. 

26. 

[Ix]

 

Rx Only - This command tells the Rx from Tx (group) video 
to display. 

Command Format:  [Ix] 

x =  Group number (TX units) 

x = 1~64 play video from source (x is 1 or 2 digits) 
x = 0 is NOT valid, returns [ER] 

Example: 

Tell the RX to display video from Tx (group) 12. 

[I12] 

Returns [ ] upon execution. 

27. 

[DB (

xx…x)]

 

Rx Only - This command forwards command data to the Rx 
CEC daughter board. The data within parentheses is the 
data seen by the daughter board. See the CEC data 
section for CEC board internal commands. 

Command Format:  [DB (x

x…x)] 

x =  CEC board command 

[DB (TVx)] ......................... TV On/Off 

[DB (TV1,x)] ...................... TV On+Input Select 

[DB (TV1,x,y,z)] ................ Power up configuration 

[DB (TV1,xx,xx,xx,xx)]....... Custom CEC command 

Example: 

Send the following to request the CEC board version: 

[DB (VER)] 

Example: 

Turn off all the TVs that display the video from the 
MT319-401 in slot 4 by sending the following: 

[DB (TV0)] 

28. 

[DHCP x]

 

This command enables/disables DHCP mode. If DHCP is 
enabled, the network assigns the IP address. By default, 
DHCP is disabled. If DHCP is enabled, it is very difficult to 
determine which Tx units is which IP. It is best to assign a 
fixed IP and disable the DHCP mode. 

Command Format:  [DHCP x] 

x =  DHCP mode (0=fixed IP, 1=network assigned) 

Example: 

Disable DHCP mode by sending the following: 

[DHCP 0]  returns [ ] 

Send the following to read the DHCP setting: 

[DHCP] 

returns [0] or [1] 

Содержание MT319-401

Страница 1: ...r a Class B digital device pursuant to Part 2 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial en...

Страница 2: ...1 Compatibility HDTV Resolution 720p to 1080p PC Resolution 1024x768 to 1400x1050 Table 1 MT319 401 General Mechanical MT319 401 Slots 1 Weight 0 8 lb 0 36 kg Connector Panel Black Anodized T Operatin...

Страница 3: ...5 2 1 RS232 TCP Interface This section lists all the RS232 TCP control and configuration command formats and their ranges The TCP IP ports have the following default settings IP address 192 168 10 84...

Страница 4: ...third party control systems Common Commands 1 C This command displays a user formatted status of the card Command Format Cii Example Display the status of the MT319 401 card in slot 4 by sending the...

Страница 5: ...ecuted by all cards in the group The is no feedback with group commands and not all cards or commands support group features Command Format GROUPxCii x Group ID x from 1 to 8 Example Assign the card i...

Страница 6: ...401 Tx are executed by all Rx units on the same group 17 TVx This command uses CEC commands to turn the TV connected to an Rx unit on or off When sent to a Tx unit using the AV network command all Rx...

Страница 7: ...matching the y output switches to display the video stream that is associated with the x input Broadcast to port 30310 Command Format IxOy x Group number TX units x 1 64 play video from source x is 1...

Страница 8: ...mand Format SFT Example SFT This is the equivalent of cycling the power If network changes were made using the SET command the new changes take effect 26 Ix Rx Only This command tells the Rx from Tx g...

Страница 9: ...transmitter Command Format STREAM x x Mode x 0 3 0 Loop Out on and Network on default 1 Loop Out only 2 Network Out only 3 Both off Example Set the Tx stream to output on the network only STREAM s ret...

Страница 10: ...Return firmware version CEC Commands RX ONLY 17 TVx Turn TV on or off 18 TV1 x Turn on TV and switch inputs 19 TV1 x y z Configure CEC startup 20 TV1 xx Send custom CEC hex code AV Network Communicat...