Altinex MT319-401 Скачать руководство пользователя страница 5

MT319-401 

User’s Guide

 

400-0698-001 

 

 
 
 
 
 
 

 

3. 

[CiS] 

This command saves the current card configuration. The 
saved configuration is restored after the system is reset or 
powered off, then on.   

Command Format: [CiiS] 

Cn  = Card ID (n = # from 1 to max slots) 

= Save configuration 

This command does not apply to the MT319-401. 

4. 

[…S]

 

– SAVE 

This command saves the configuration command being 
sent in memory.  Send [I1O1C8S] and after reset or power 
up, Input 1 is connected to Output 1 on C8.  This command 
only saves the Input 1 to Output 1 connection above. Use 
the [CiiS] command to save all current settings. 

This command does not apply to the MT319-401. 

5. 

[DISP]

 

This command returns the card information that is 
displayed on the enclosure LCD window. 

Command Format: [DISPCii] 

Read what is displayed on the LCD by sending [DISPC4]. 
The feedback displays the text for both the top row and the 
bottom row separated by commas. 

 [MT319-401,HDMI OVER IP TX C04] 

6. 

[FRST]

 

This command clears the card, restoring the factory default 
settings. 

Command Format:  [FRSTCii] 

Example: 

To clear the card in slot 4, send [FRSTC4]. The card in slot 
4 is now returned to its default factory values. 

7. 

[GROUP]

 

This command assigns a card to a group of cards. If a 
group command is sent to the enclosure and the group 
number matches, the group command is executed by all 
cards in the group. The is no feedback with group 
commands and not all cards or commands support group 
features. 

Command Format:  [GROUPxCii] 

= Group ID  (x = # from 1 to 8) 

Example: 

Assign the card in slot 4 to group 2 by sending 
[GROUP2C4]. Execute a group command by sending the 
command with a group ID. For example, [ON1G4]. 

8. 

[HWEN]

 

This command enables or disables the card hardware, 
excluding the main microprocessor. Power to video and 
audio circuitry is turned off. Use for saving power but to 
keep response time short returning to normal operation. 

This is not a group command. 

Command Format:  [HWENxCii] 

= On/off  (1 = on, 0 = off) 

Command Format:  [HWENxnCii] 

= On/off  (1 = on, 0 = off) 

= Output No  (n = 1 or 2) 

Example: 

Disable the hardware to the card in slot 4 by sending the 
following command: 

[HWEN0C4] 

9. 

[MOD]

 

This command returns the card model number. 

Command Format:  [MODCii] 

Example: 

Read the model of the card in slot 4 by sending [MODC4]; 
feedback is like the following: 

[MT319-401C04] 

10. 

[PRG]

  

This command puts the card into firmware update mode. 
Only use when working with Altinex Technical Support. 

Command Format:  [PRGCii] 

11. 

[PWR]

 

Display card power consumption in watts. 

Command Format:  [PWRCii] 

Example: 

Read the power consumption of the card in slot 4 by 
sending [PWRC4]; feedback is like the following: 

[4.59WC04] 

12. 

[PWRM]

 

Same as the [PWR] except in milliwatts. 

Command Format:  [PWRMCii] 

Example: 

Read the power consumption (in milliwatts) of the card in 
slot 4 by sending [PWRMC4]; feedback is like the following: 

[4596mWC04] 

Содержание MT319-401

Страница 1: ...r a Class B digital device pursuant to Part 2 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial en...

Страница 2: ...1 Compatibility HDTV Resolution 720p to 1080p PC Resolution 1024x768 to 1400x1050 Table 1 MT319 401 General Mechanical MT319 401 Slots 1 Weight 0 8 lb 0 36 kg Connector Panel Black Anodized T Operatin...

Страница 3: ...5 2 1 RS232 TCP Interface This section lists all the RS232 TCP control and configuration command formats and their ranges The TCP IP ports have the following default settings IP address 192 168 10 84...

Страница 4: ...third party control systems Common Commands 1 C This command displays a user formatted status of the card Command Format Cii Example Display the status of the MT319 401 card in slot 4 by sending the...

Страница 5: ...ecuted by all cards in the group The is no feedback with group commands and not all cards or commands support group features Command Format GROUPxCii x Group ID x from 1 to 8 Example Assign the card i...

Страница 6: ...401 Tx are executed by all Rx units on the same group 17 TVx This command uses CEC commands to turn the TV connected to an Rx unit on or off When sent to a Tx unit using the AV network command all Rx...

Страница 7: ...matching the y output switches to display the video stream that is associated with the x input Broadcast to port 30310 Command Format IxOy x Group number TX units x 1 64 play video from source x is 1...

Страница 8: ...mand Format SFT Example SFT This is the equivalent of cycling the power If network changes were made using the SET command the new changes take effect 26 Ix Rx Only This command tells the Rx from Tx g...

Страница 9: ...transmitter Command Format STREAM x x Mode x 0 3 0 Loop Out on and Network on default 1 Loop Out only 2 Network Out only 3 Both off Example Set the Tx stream to output on the network only STREAM s ret...

Страница 10: ...Return firmware version CEC Commands RX ONLY 17 TVx Turn TV on or off 18 TV1 x Turn on TV and switch inputs 19 TV1 x y z Configure CEC startup 20 TV1 xx Send custom CEC hex code AV Network Communicat...