MT319-401
User’s Guide
400-0698-001
5
3.
[CiS]
This command saves the current card configuration. The
saved configuration is restored after the system is reset or
powered off, then on.
Command Format: [CiiS]
Cn = Card ID (n = # from 1 to max slots)
S
= Save configuration
This command does not apply to the MT319-401.
4.
[…S]
– SAVE
This command saves the configuration command being
sent in memory. Send [I1O1C8S] and after reset or power
up, Input 1 is connected to Output 1 on C8. This command
only saves the Input 1 to Output 1 connection above. Use
the [CiiS] command to save all current settings.
This command does not apply to the MT319-401.
5.
[DISP]
This command returns the card information that is
displayed on the enclosure LCD window.
Command Format: [DISPCii]
Read what is displayed on the LCD by sending [DISPC4].
The feedback displays the text for both the top row and the
bottom row separated by commas.
[MT319-401,HDMI OVER IP TX C04]
6.
[FRST]
This command clears the card, restoring the factory default
settings.
Command Format: [FRSTCii]
Example:
To clear the card in slot 4, send [FRSTC4]. The card in slot
4 is now returned to its default factory values.
7.
[GROUP]
This command assigns a card to a group of cards. If a
group command is sent to the enclosure and the group
number matches, the group command is executed by all
cards in the group. The is no feedback with group
commands and not all cards or commands support group
features.
Command Format: [GROUPxCii]
x
= Group ID (x = # from 1 to 8)
Example:
Assign the card in slot 4 to group 2 by sending
[GROUP2C4]. Execute a group command by sending the
command with a group ID. For example, [ON1G4].
8.
[HWEN]
This command enables or disables the card hardware,
excluding the main microprocessor. Power to video and
audio circuitry is turned off. Use for saving power but to
keep response time short returning to normal operation.
This is not a group command.
Command Format: [HWENxCii]
x
= On/off (1 = on, 0 = off)
Command Format: [HWENxnCii]
x
= On/off (1 = on, 0 = off)
n
= Output No (n = 1 or 2)
Example:
Disable the hardware to the card in slot 4 by sending the
following command:
[HWEN0C4]
9.
[MOD]
This command returns the card model number.
Command Format: [MODCii]
Example:
Read the model of the card in slot 4 by sending [MODC4];
feedback is like the following:
[MT319-401C04]
10.
[PRG]
This command puts the card into firmware update mode.
Only use when working with Altinex Technical Support.
Command Format: [PRGCii]
11.
[PWR]
Display card power consumption in watts.
Command Format: [PWRCii]
Example:
Read the power consumption of the card in slot 4 by
sending [PWRC4]; feedback is like the following:
[4.59WC04]
12.
[PWRM]
Same as the [PWR] except in milliwatts.
Command Format: [PWRMCii]
Example:
Read the power consumption (in milliwatts) of the card in
slot 4 by sending [PWRMC4]; feedback is like the following:
[4596mWC04]