User’s Guide

    

400-0446-002 

 

 
 
 
 
 
 

Welcome! 

We greatly appreciate your purchase of the AC301-201 TCP/IP to RS-232 
Adapter. We are sure you will find it reliable and simple to use. Superior 
performance for the right price, backed by solid technical and customer 
support is what ALTINEX has to offer. 

We are committed to providing our customers with 
Signal Management Solutions

®

 to the most demanding audiovisual 

installations at very competitive pricing and we welcome you to join the 
ranks of our many satisfied customers throughout the world. 

1. Precautions and Safety Warnings 

Please read this manual carefully before using your AC301-201. Keep this 
manual handy for future reference. These safety instructions are to ensure 
the long life of your AC301-201 and to prevent fire and shock hazards. Please 
read them carefully and heed all warnings. 

1.1 General 

 

Qualified ALTINEX service personnel or their authorized 
representatives must perform all service. 

1.2 Installation Precautions 

 

To prevent fire or shock, do not expose this unit to water or moisture. 
Do not place the AC301-201 in direct sunlight, near heaters or 
heat-radiating appliances, or near any liquid. Exposure to direct 
sunlight, smoke, or steam can harm internal components. 

 

Handle the AC301-201 carefully. Dropping or jarring can cause damage. 

 

Do not pull the cables that are attached to the AC301-201. 

1.3 Cleaning 

 

Clean only with a dry cloth. Never use strong detergents or solvents, 
such as alcohol or thinner. Do not use a wet cloth or water to clean the 
unit. Do not open the unit to clean. 

1.4 FCC Notice 

 

This device complies with Part 15 of the FCC Rules. Operation is 
subject to the following two conditions: (1) This device may not cause 
harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation. 

 

This equipment has been tested and found to comply with the limits for 
a Class A digital device, pursuant to Part 15 of the FCC Rules. These 
limits are designed to provide reasonable protection against harmful 
interference when the equipment is operated in a commercial 
environment. This equipment generates, uses, and can radiate radio 
frequency energy and, if not installed and used in accordance with the 
instructions found herein, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is 
likely to cause harmful interference in which case the user will be 
required to correct the interference at his own expense. 

 

Any changes or modifications to the unit not expressly approved by 
ALTINEX, Inc. could void the user’s authority to operate the 
equipment. 

 

 

 

2. Installation Procedures 

Step 1. 

Connect the AC301-201 directly to the 9-pin D-sub connector of the MultiTasker enclosure or other RS-232 serial controlled device. If connecting 
through a cable and not directly to the MultiTasker, make sure the cable has a conductor for pin 9 or use the external adapter. 

Step 2. 

If controlling a device other than a MultiTasker enclosure, it is necessary to connect the external power adapter to the DC power jack located on the 
side of the AC301-201. The LED should be on and red when power is present. The LED inside the AC301-201 is located near the RJ-45 connector and 
is visible through the seam in the enclosure. 

Step 3. 

Connect the RJ-45 connector on the opposite end of the AC301-201 to the LAN using a standard UTP (CAT-5) type cable.  

Step 4. 

The AC301-201 is now operational. The default IP is assigned by the LAN and uses port number 10001 for the TCP/IP connection. 

Note:  The IP can be preset by ALTINEX at the time of purchase. For best results, have a fixed IP assigned by your IT department and then set by 

ALTINEX prior to shipping.  See Section 7.1 of the online manual for changing the configuration using the DeviceInstaller application or use 
the TELNET option below. 

Step 5. 

Change the IP address or baud rate using TELNET from a command prompt. The TELNET port is "9999". 

A. 

At the command prompt enter "TELNET", the current IP, and port 9999. Example: "C:\> TELNET 192.168.1.155  9999" 

B. 

Press "Enter" when prompted to enter the setup mode.  

C. 

Select the option to change, and at each prompt enter the new value or just press "Enter" to leave unchanged. 

Option "0 Server"................................ Change IP, mask, and gateway. (set IP 0.0.0.0 for DHCP) 

Option "1 Channel 1" ......................... Change baud rate 

Option "8 Exit without save".............. Cancel changes and exit setup mode 

Option "9 Save and Exit" .................... Save changes and exit  

The changes may take a few seconds to be recognized by the network. 

3. Limited Warranty/Return policies 

Please see the ALTINEX website at 

www.altinex.com

 for details on warranty and return policies. 

Содержание AC301-201

Страница 1: ...es and can radiate radio frequency energy and if not installed and used in accordance with the instructions found herein may cause harmful interference to radio communications Operation of this equipm...

Страница 2: ...90 non condensing MTBF calculations 40 000 hrs Table 2 AC301 201 Mechanical Electrical AC301 201 Input Output Signal Serial 9 pin D Sub RS 232 Standard Ethernet LAN TCP IP 10 100 Mbps Default Setting...

Страница 3: ...network LAN The IP address Internet Protocol address may be set automatically or assigned manually during the initial installation The AC301 201 is compact and easy to use It offers a male 9 pin D Sub...

Страница 4: ...AC301 AC301 AC301 AC301 201 201 201 201 User s Guide 400 0446 002 4 6 Application Diagrams Diagram 1 Typical Setup AC301 201 INTERNET MULTITASKER...

Страница 5: ...AC301 AC301 AC301 201 201 201 201 User s Guide 400 0446 002 5 Diagram 2 Internal View DC 6V RX DATA IN DATA OUT AC301 201 TX POWER ETHERNET TTL TX 9 PIN D Sub ETHERNET RJ 45 POWER JACK TRANCEIVER to R...

Страница 6: ...a few seconds The IP Address 7 Once the device is located click on the device in the installer window and make note of the IP address Note If you want to assign the IP manually click Assign IP This me...

Страница 7: ...COM Setup select the TCP option Enter the IP address for the Host and port number 10001 is the default from above for the Port The IP address 192 168 1 100 is only an example Your IP address will var...

Страница 8: ...a MultiTasker then the external power adapter must be connected Connect the power adapter to the AC301 201 If the LED is still not on see Cause 4 Cause 4 The AC301 201 has a problem Solution If there...

Отзывы: