Name
Value
Description
Receiver common mode
voltage
Tri-State
0.82V
1.1v
Specifies the RX common mode voltage.
Receiver termination
resistance
OCT_85_OHMS
OCT_100_OHMs
OCT_120_OHMS
OCT_150_OHMS
Indicates the value of the termination resistor for
the receiver.
Receiver DC
0-4
Sets the equalization DC gain using one of the
following settings:
• 0: 0 dB
• 1: 3 dB
• 2: 6 dB
• 3: 9 dB
• 4: 12 dB
Receiver static equalizer
setting:
0-15
This option sets the equalizer control settings. The
equalizer uses a pass band filter. Specifying a low
value passes low frequencies. Specifying a high
value passes high frequencies.
Analog Parameters for Arria V, Arria V GZ, and Stratix V Devices
Click on the appropriate links to review the analog parameters for these devices.
Related Information
•
Analog Settings for Arria V Devices
on page 19-2
•
Analog Settings for Arria V GZ Devices
on page 19-11
•
Analog Settings for Stratix V Devices
on page 19-34
10GBASE-R PHY Interfaces
This section describes the 10GBASE-R PHY interfaces.
The following figure illustrates the top-level signals of the 10BASE-R PHY; <
n
> is the channel number.
UG-01080
2015.01.19
10GBASE-R PHY Interfaces
3-13
10GBASE-R PHY IP Core
Altera Corporation
Send Feedback