For more information about _hw.tcl files, refer to refer to the
Component Interface Tcl Reference
chapter
in volume 1 of the
Quartus II Handbook
.
Related Information
Component Interface Tcl Reference
PHY for PCIe (PIPE) Input Data from the PHY MAC
Input data signals are driven from the PHY MAC to the PCS. This interface is compliant to the
appropriate PIPE interface specification.
For more information about the Avalon-ST protocol, including timing diagrams, refer to the
Avalon
Interface Specifications
.
Table 8-3: Avalon-ST TX Inputs
Signal Name
Direction
Description
Gen1 and Gen2
pipe_txdata[31:0],[15:0]
, or
[7:0]
Input
Parallel PCI Express data input bus. For the 16-bit
interface, 16 bits represent 2 symbols of transmit
data. Bits [7:0] is transmitted first; bits[15:8] are
transmitted second. Bit 0 if the first to be
transmitted. For the 32-bit interface, 32 bits
represent the 4 symbols of TX data. Bits[23:16] are
the third symbol to be transmitted and bits [31:24]
are the fourth symbol.
pipe_txdatak[(3:0],[1:0]
or
[0]
Input
For Gen1 and Gen2, data and control indicator for
the received data. When 0, indicates that
pipe_
txdata
is data, when 1, indicates that
pipe_
txdata
is control.
For Gen3, Bit[0] corresponds to
pipe_
txdata[7:0]
, bit[1] corresponds to
pipe_
txdata[15:8]
, and so on.
pipe_txcompliance
Input
Asserted for one cycle to set the running disparity
to negative. Used when transmitting the
compliance pattern. Refer to section 6.11 of the
Intel PHY Interface for PCI Express (PIPE)
Architecture
for more information.
pipe_tx_data_valid[<n>-1:0]
Input
For Gen3,
pipe_tx_data_valid[<n>-1:0]
is
deasserted by the MAC to instruct the PHY to
ignore
pipe_txdata
for one clock cycle. A value of
0 indicates the PHY should use the data. A value of
1 indicates the PHY should not use the data.