4.3.2.

 

Host Interface (Pins #27 and #79) 

 

This  Interface  allows  both  the  Host  and  the  modem  to  enter  their  power 
consumption  savings  states  whenever  possible,  in  order  to  optimize  power 
consumption. The idea is to have a simple interface allowing the host and modem 
to wake each other up when required and to acknowledge once ready. 
Due to the GPIOs quantity limitation in most Host processors this simple interface 
only uses two lines.  
For  a  more  detailed  explanation  on  this  interface  implementation  please  check 

“Altair_SW_219_Rev2_host_interface_HL_design”

 application note. 

 

4.3.3.

 

UIM Interface (Pins #4, #59, #60, #5 and #7) 

 

This Interface allows the use of an external 1.8V sim card on the application board.  
The external SIM is powered from an internal 1.8V regulator (VSIM (pin# 7). 
Please note the modem only supports 1.8V SIM/eSIM cards and requires the use of 
external  pull  up/down  resistors  to  maintain  the  polarity  of  the  SIM_CLK  line  for 
eSIM devices. 
Regular SIM devices may be used externally to the module, but since all modem 
digital  IOs  are  not  maintained  during  hibernation  states,  if  there  is  a  need  to 
maintain the SIM ON during modem hibernation states, it is necessary to add an 
external latch to keep the UIM_CLK value. 

4.3.4.

 

USB Interface (Pins #13 and #14) 

The  ALT1210MOD-VZ-01  module  also  supports  USB  2.0  interface  (primarily used 
for production and debug purposes due to the extra power consumption). 
The USB interface requires proper SW drivers. For more information on the proper 
drivers to be used please contact Altair application team. 

4.3.5.

 

UART1 (Pins #11, #65, #10, #64 and optional #80, #26, #82, #25) 

The  UART1  interface  is  a  1mbps  UART  interface.  It  can  be  used  as  a  two  pin 
interface, 4 pin interface or even 8 pin interface. 

4.3.6.

 

UART2 (Pins #8 and #9) 

The UART2 interface is a 1mbps UART interface. It can be used only as a simple two 
pin interface. 

4.3.7.

 

I2C (Pins #19 and #73) 

The ALT1210MOD-VZ-01 module can also operate as the Master of an I2C bus to 
control  external  devices.  These  two  signals  require  external  10k  ohm  pull-up 
resistors to 1V8_IO_IN rail. 
 

Содержание ALT1210MOD-VZ-01

Страница 1: ...THE WORLD S LTE LEADER 6 Ha harash Street P O Box 7158 Hod Hasharon 45240 ISRAEL Tel 972 74 780 0800 Fax 972 9 740 3049 ALT1210MOD VZ 01 User Module Jan 2018...

Страница 2: ...which Altair products or services are used Information published by Altair regarding third party products or services does not constitute a license from Altair to use such products or services or a w...

Страница 3: ...or Proprietary and Confidential 3 Document Revision Control Edition Issued By Date Description 0 1 Alon K 17 12 2017 Initial specification 0 2 Alon K 11 01 2018 Minor modifications and additions 1 0 A...

Страница 4: ...12 4 1 5 General Power Related Guidelines 14 4 2 Power up and Power Down Sequences 15 4 3 Specific Interfaces Guidelines 15 4 3 1 RF Pin 36 15 4 3 2 Host Interface Pins 27 and 79 16 4 3 3 UIM Interfa...

Страница 5: ...ALT1210MOD VZ 01 User Module Rev 1 0 Altair Semiconductor Proprietary and Confidential 5 5 1 2 GCF 18 5 1 3 Verizon wireless conformance 18...

Страница 6: ...User Module Rev 1 0 Altair Semiconductor Proprietary and Confidential 6 1 Scope The purpose of this document is to be used as a basic user manual for designers developing products based on the ALT1210...

Страница 7: ...requiring real time communication along with long battery life 2 1 General Features Frequency range B4 UL 1710 1755MHz DL 2110 2155MHz B13 UL 777 787MHz DL 746 756MHz LTE Category Category 1 SW upgra...

Страница 8: ...lectrical Specification Item Min Typ Max Units Notes Required Power Supplies Rating VBAT 3 2 3 8 4 3 V If USB interface is not used the Vin voltage can be further reduced up to 3 0V IVBAT 400 mA VPA 3...

Страница 9: ...miconductor Proprietary and Confidential 9 3 Pinout 3 1 Land Pattern Module size 15 X 15 mm Pad size o Signal pin 0 7 X 0 5 mm o Thermal pin 1 0 X 1 0 mm Pitch o same loop 0 8 mm o 1st to 2nd loop 1 0...

Страница 10: ...GND FEM_CTRL5 FEM_CTRL2 FEM_CTRL3 FEM_CTRL6 FEM_CTRL7 FEM_CTRL4 GND SAR_VAINP2 GND FEM_CTRL1 GND GND GND GND GND GND VPA GND PCM_SYNC SPIM_CLK SPIM_EN_1 GND GND GND 1 2 VBAT VBAT VBAT 9 VDD_RET_IN 3...

Страница 11: ...out signal SF_nWP IO2 Serial flash write protect signal SF_nHOLD IO3 Serial flash HOLD signal SF_nCS1 Serial flash chips select signal SPI_M_CLK SPI master interface clock signal SPI_M_MOSI SPI master...

Страница 12: ...mize BOM cost or size at the expense of power consumption it is possible to supply this rail directly from the battery Host needs to disable the Modem when the battery voltage drops towards 3 0V In ap...

Страница 13: ...vel The second option is using an external supply The motivation is to allow shutting down additional circuits inside the Module in order to achieve an even lower floor power consumption in lite hiber...

Страница 14: ...70 FEM_CTRL2 31 Host GPIO1 1 8V For IOs and DDR DC DC 3 0V For RF PAs GPIO2 En Vout Vin DC DC En Vout Vin DC DC En Vout Vin 3 2V Main supply RETLE_N_OUT RETLE_N_IN FEM_CTRL0 21 76 22 VO18R_OUT 62 It r...

Страница 15: ...e stable before the shutdown pin is set low and the system boots up The proper power down sequence would be the opposite Shutdown pin is set high shutting the modem internal supplies and modem VPA shu...

Страница 16: ...rs to maintain the polarity of the SIM_CLK line for eSIM devices Regular SIM devices may be used externally to the module but since all modem digital IOs are not maintained during hibernation states i...

Страница 17: ...Z 01 has 4 ADC converters to measure external signals The readings can be done by AT command or from the application layer 4 3 10 SPI Master Pins 107 108 54 55 and 63 This is a 4 wire bus with two chi...

Страница 18: ...on to remove or install the module 4 This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it should be installed and operated with a minimum distance o...

Отзывы: