Appendix A
– Equipment Log
RPV311
RPV311-TM-EN-6
341
1
EQUIPMENT LOG
The equipment log contains information about:
Threshold violations, fault and disturbance triggers and data recording;
Data record transfer (including the IP address to which data has been transferred);
Access to the unit's configuration pages (including IP address of which the access was performed);
Alarms and the results of auto-diagnosis routines;
Power-up and shutdown.
The equipment log cannot be erased by the user. Its capacity is enough for approximately 5 years of typical
use, with past events being erased if memory space is needed.
Log
Description
Cause
000
Internal failure
Hardware or processing failure
001
Invalid key
The key applied to the equipment is not valid
010
Power up
Equipment power-up
011
Power off
Equipment power-off
012
Auto power-off (primary power failure)
Battery operated power time run-out
013
Emergency power-off (low battery)
Battery charge below expected, equipment
shut off automatically
020
Primary power OK
Primary power supply voltage equipment
021
Primary power NOK
Battery backup equipment
029
Battery status [value: ]
Battery voltage indication
030
Temperature normal [value: ]
Temperature return to normal values
031
Temperature high [value: ]
Internal temperature high
039
Temperature status [value: ]
Equipment temperature indication
050
Equipment ready
Equipment normal operation
051
Equipment not ready
Equipment is not operational
100
IRIG-B signal
Equipment is connected to IRIG-B signal
Содержание Reason RPV311
Страница 2: ......
Страница 15: ...INTRODUCTION CHAPTER 1...
Страница 34: ...SAFETY INFORMATION CHAPTER 2...
Страница 45: ...HARDWARE DESIGN CHAPTER 3...
Страница 56: ......
Страница 57: ...CONFIGURATION CHAPTER 4...
Страница 75: ...RPV311 Chapter 4 Configuration RPV311 TM EN 6 75 Figure 21 Email Fax configuration...
Страница 77: ...RPV311 Chapter 4 Configuration RPV311 TM EN 6 77 Figure 22 Adding and editing voltage circuits...
Страница 117: ...OPERATION CHAPTER 5...
Страница 121: ...RPV311 Chapter 5 Operation RPV311 TM EN 6 121 Figure 46 Status monitoring sequence...
Страница 123: ...RPV311 Chapter 5 Operation RPV311 TM EN 6 123 Figure 47 Monitoring sequence...
Страница 126: ...Chapter 5 Operation RPV311 126 RPV311 TM EN 6 Figure 49 Records monitoring sequence harmonics flicker and SOE...
Страница 128: ...Chapter 5 Operation RPV311 128 RPV311 TM EN 6 Figure 50 Equipment settings monitoring sequence...
Страница 129: ...RPV311 Chapter 5 Operation RPV311 TM EN 6 129 Figure 51 Circuit and channel settings monitoring sequence...
Страница 130: ...Chapter 5 Operation RPV311 130 RPV311 TM EN 6 Figure 52 Relays PMU and MODBUS settings monitoring sequence...
Страница 132: ...Chapter 5 Operation RPV311 132 RPV311 TM EN 6 Figure 53 General information monitoring sequence...
Страница 155: ...RECORDS CHAPTER 6...
Страница 172: ......
Страница 173: ...TW FAULT LOCATOR CHAPTER 7...
Страница 183: ...PMU CHAPTER 8...
Страница 189: ...MODBUS CHAPTER 9...
Страница 193: ...DNP3 CHAPTER 10...
Страница 196: ......
Страница 197: ...GOOSE MESSAGE DETECTION CHAPTER 11...
Страница 200: ......
Страница 201: ...SOFTWARE RPV TOOLS CHAPTER 12...
Страница 228: ......
Страница 229: ...SOFTWARE RPV MANAGER CHAPTER 13...
Страница 249: ...COMMUNICATIONS CHAPTER 14...
Страница 261: ...INSTALLATION CHAPTER 15...
Страница 295: ...Chapter 15 Installation RPV311 RPV311 TM EN 6 295 Figure 138 RA331 RA332 and RA333 dimensions...
Страница 299: ...MAINTENANCE AND TROUBLESHOOTING CHAPTER 16...
Страница 310: ...TECHNICAL SPECIFICATIONS CHAPTER 17...
Страница 329: ...Chapter 17 Technical Specifications RPV311 RPV311 TM EN 6 329 Figure 142 RA331 RA332 and RA333 dimensions...
Страница 331: ...RPV311 Chapter 17 Wiring Diagrams WIRING DIAGRAMS CHAPTER 18...
Страница 340: ...APPENDIX A...