![Alps Electric SPEEDGLIDER Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/alps-electric/speedglider/speedglider_operators-manual_2908782038.webp)
AIR LOGIC POWER SYSTEMS (ALPS)
THE RESULTS MENU
SPEEDGLIDER
ADVANCED OPERATOR MANUAL
37
TM 2012-005 REV00 © 10/25/2012
Test Results Menu
Test Results Introduction
Test results are where comparative data on leak test results is viewable. Based on this information an operator or
supervisor can make quality control decisions on current production runs.
Test Result Descritption Table
Test Result Display
Description
1. Last Test Detail
Provides real time test details, overall or per head
2. Detail Timers
•
CYCLE TIMES:
The “Last Test Time” is measured from servo “Go”
signal to test head 1 probe retract time expires. The Last Cycle Time is
from the servo Go to the Servo returned to zero. These perimeters can
help determine available leak test time.
•
Servo Times:
These time are used to help determine servo Alarms the
key is to have “Spare Time at Start and End” to avoid Servo timing
Alarms. See information help screens on SpeedGlider HMI on how to
use spare time.
•
Test Times:
The Cycle Extend, Fill Time, Test 1, Test 2, and Cycle
Retract Time shows the current time settings for easy comparison to
the cycle time. These times combined should not exceed the cycle
time, however in using all available test time it should be close
3. Counters Main
Total counts, overall and per test head, for leaks test performed, accepted,
rejected and reject %
4. Counters Self-Test
Total counts, overall and per self-test head, for self- test performed, passed,
rejected and self-test reject %.
5. Counters Details
Total counts for each possible type of leak test reject
6. Recent Reject
The latest reject type, the peak pressure value, the pressure decay % at the
end of Test 1 and Test 2, and on what head it occurred on.
7. Counters Alarm
Total counts (how many times they occurred) for every possible alarms
8. Alarm Log
Alarm tracking time stamp details