AL110 ANSI   
ELECTRIC STRIKE

 

 

 

 
DOOR LATCH POSITION 

1mm

Keeper

D oor latch

Front face of

strike keeper

Keeper

D oor Fram e

D oor

Figure 1

 

As shown above, there must be a 1mm gap between the door latch and the front face of strike keeper to 
prevent the door from exerting pressure on the keeper when door is closed. 

 

MOUNTING STEPS OF STRIKE 

1).

           

For aluminum or metal door frame brackets are supplied for assembly, refer to Figure 2.  

        For timber door frame refer to Fig. 3. mark and drill the hole sizes as indicated on Figure 2 and Figure 3. 
2). 

         

Make sure electrical connections are followed correctly. 

3).

                               

When the door is closed, ensure that there is no pressure on the front face of strike keeper. 

4). 

         

When all the above checks are completed, secure the strike with supplied screws and recheck operation. 

 

POWER INPUT 12 VDC or 24 VDC SUPPLY: 

 

 

 

 

 

 

 

Note: There is no polarity on power input.    AL110 model is not equipped with monitoring sensor. 

 
INSTALL ON METAL OR ALUMINUM DOOR FRAME 

38

156 (A) or 232.3 (B)

124.7 (A) or 201(B)

86

6.5

Mounting on metal door

32.7(A) or 36(B)

17(A) or 18.8(B)

Mounting on aluminum or PVC door

Latch area

Front face of strike keeper

10 x  6 csk screw hole 2 places.

Note:  1. (A) refer to small faceplate with actual size 123.7 x 31.7 x 3mm

Figure 2

           2.

 

(B) refer to large faceplate with actual size  200.0 x 35.0 x 3mm

           3.

 

All sizes in millimeter.

     

20

.5

25mm, 50mm, 75mm extension
 lips are available options 

Depth of lip cutout will vary
due to width of door frame 
and mounting technique

Remove rubber plug 
prior to assembly of 
extension lips (2 places). 

 

 