hypercharger - Operation Instructions and Installation Guide
Version 1-1C
3
Product
description
Page 17 of 57
All rights reserved. The reproduction of this document, also partially, is allowed only with authorization by alpitronic s.r.l.
Identifier
Description
-KF3
CTRL_IO control board
-QB2.1, -QB2.2
DC-outlet 1 contactors
-QB3.1, -QB3.2
DC-outlet 2 contactors (optional, only when DC-outlet 2 is present)
-QB4.1, -QB4.2
DC-link contactors
-QB7
Contactors for AC charging (optional, only when AC-socket is present)
-XD3.1
DC- pole for vehicle cable connection XD5 (DC-outlet 1)
-XD3.2
DC-busbar
– pole for vehicle cable connection XD5 (DC-outlet 1)
-XD4.1
DC- pole for vehicle cable connection XD6 (DC-outlet 2)
-XD4.2
DC-busbar
– pole for vehicle cable connection XD6 (DC-outlet 2)
Table 5:
DC output switchgear components for hypercharger HYC_075 and HYC_150
The following figure shows the AC input switchgear of the HYC_075 and the HYC_150:
Figure 11:
AC input switchgear of the HYC_075 and the HYC_150
The following table describes the single components highlighted in the figure above:
Identifier
Description
-FA1
Lightning protection and EMI filter device
-FB1
32A circuit breaker with fault current monitoring AC charging / 4P
-FB2
16A circuit breaker with fault current monitoring for auxiliary 230Vac / 4P
-QA1, -QA2
125A circuit breaker / 3P / 16kA
-QB1
250A main switch / 4P
-TB1
Auxiliary 24V power supply
-XD1
Mains input busbars
-XF1
Ethernet network dose RJ45
Table 6:
AC input switchgear components for hypercharger HYC_075 and HYC_150