![Alpha Alpha Top Easy-Flue 1000 mm Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/alpha/alpha-top-easy-flue-1000-mm/alpha-top-easy-flue-1000-mm_installation-instructions-manual_2905038001.webp)
Installation Instructions
Alpha Top Easy-Flue 1000 mm
(Kit Part No. 6.1000382)
For use with Alpha CB/C/SY boilers only
KIT CONTENTS
1. GENERAL
a.
The Alpha Easy-Flue is suitable for straight horizontal flues only and can be extended up to the maximum lengths
given in Fig. 1 and 2.
b.
The Easy-Flue includes a 90° bend, (no separate 90° bend is required).
c.
Ensure that there is a slight downward slope of the flue to outside.
d.
The flue system must be installed in accordance with BS 5440:1.
e.
The Easy-Flue is suitable for use in the flue length ranges given in Fig. 1 and 2.
Fig. 1 - Rear Flue
Fig. 2 - Side Flue
Note: Where the length is less than the minimum or more than the maximum, refer to Appendix 2.