SNQ-60x0-320F Series Data Center Switch
Hardware Installation Guide
19
Category
Specification
Description
Efficiency
89% to 91% (at 220V)
Typical Heat Dissipation
SNQ-6070-320F
817 BTU/hr (32 QSFP+ ports with Twinax at
100% load)
929 BTU/hr (32 QSFP+ ports with SR4 at
100% load)
SNQ-60A0-320F
842 BTU/hr (32 QSFP+ ports with Twinax at
100% load)
963 BTU/hr (32 QSFP+ ports with SR4 at
100% load)
Maximum Heat Dissipation
1,206 BTU/hr
Cooling
Number of Fan Modules
5 (4 Included, 1 Excluded)
Types of Fan Modules
Forward or Reversed Airflow
Hot Swappable
Yes
Fan Speeds
Programmable High and Low Speed
Noise Factor
All Fans at Low Speed
59.50 dBA
All Fans at High Speed
76.10 dBA
Environment
Dimensions
44mm (H) x 440mm (W) x 487.4mm (D)
Weight
9.29 kg (with 2 AC PSUs and 5 Fans installed)
Operating Temperature
0°
C to 45
°C (32°F to 113°F)
Storage Temperature
-40
°C to 70°C (-40°F to 158°F)
Operating Relative Humidity
0% to 95% (Non-condensing)
Storage Relative Humidity
0% to 95% (Non-condensing)
Altitude
0 to 3,000 meters (0 to 9,850 feet)
Regulatory Standards Compliance
The following table lists the regulatory standards compliance for switches in this series.
Specification
Description
Regulatory Compliance
Comply with CE Markings per directives 2004/108/EC and 2006/95/EC
FCC/IC Report Class A
BSMI
UL/cUL Listed Mark
CCC
CB
Safety
IEC 60950-1
EN 60950-1
UL/CSA-C22.2 NO. 60950-1-07
CNS 14336-1
GB4943.1
EMC
EN 55022/EN 55024, Class A