3.3 Viewing Operating Mode Parameters
The flow diagram below shows the viewable parameters that are scrolled through as the
program key (
P
) is pressed:
P
R
ALM 1
ALM 2
Model DS2000 DEWPOINT METER
dewTEC
P
R
ALM 1
ALM 2
Model DS2000 DEWPOINT METER
dewTEC
D E W P O IN T
P
R
ALM 1
ALM 2
Model DS2000 DEWPOINT METER
dewTEC
P
R
ALM 1
ALM 2
Model DS2000 DEWPOINT METER
dewTEC
M axim um
(H igh) value
P
R
ALM 1
ALM 2
Model DS2000 DEWPOINT METER
dewTEC
P
R
ALM 1
ALM 2
Model DS2000 DEWPOINT METER
dewTEC
M inim um
(Low ) value
P
R
ALM 1
ALM 2
Model DS2000 DEWPOINT METER
dewTEC
P
R
ALM 1
ALM 2
Model DS2000 DEWPOINT METER
dewTEC
A larm 1
Elapsed Tim e
PRESS
PRESS
PRESS
PRESS
PRESS
PRESS
PRESS
PRESS
P
R
ALM 1
ALM 2
Model DS2000 DEWPOINT METER
dewTEC
P
R
ALM 1
ALM 2
Model DS2000 DEWPOINT METER
dewTEC
A larm 2
value
P
R
ALM 1
ALM 2
Model DS2000 DEWPOINT METER
dewTEC
P
R
ALM 1
ALM 2
Model DS2000 DEWPOINT METER
dewTEC
P
R
ALM 1
ALM 2
Model DS2000 DEWPOINT METER
dewTEC
P
R
ALM 1
ALM 2
Model DS2000 DEWPOINT METER
dewTEC
A larm 1
value
P
R
ALM 1
ALM 2
Model DS2000 DEWPOINT METER
dewTEC
P
R
ALM 1
ALM 2
Model DS2000 DEWPOINT METER
dewTEC
A larm 1 H ysterisis
value
P
R
ALM 1
ALM 2
Model DS2000 DEWPOINT METER
dewTEC
P
R
ALM 1
ALM 2
Model DS2000 DEWPOINT METER
dewTEC
Total
PRESS
PRESS
PRESS
PRESS
PRESS
PRESS
PRESS
PRESS
PRESS
PRESS
A larm 2 H ysterisis
value
NOTE
: These displays
will not appear if the
Help
function is disabled
Initial Display at Start Up
. Displays your process
Dewpoint.
Maximum (High) Dewpoint since last reset. To reset,
press the (
R
) key when displayed.
Minimum (Lo) Dewpoint since last reset. To reset, press
the (
R
) key when displayed.
Accumulated time that Alarm 1 has been active since last
reset. This display format is in
mm.ss
up to 99 minutes
and 59 seconds, after which the format changes to
mmm.s
. To reset, press the (
R
) key when displayed.
Dewpoint at and above which (Process High Alarm) or at
and below which (Process Low Alarm) Alarm 1 is active.
To set press ( ) when displayed and follow the
instructions given in paragraph 3.4.
Defines the width of the hysterisis band in dewpoint
applied on the ‘safe’ side of the Alarm 1 level. Set in the
same manner as Alarm value.
Dewpoint at and above which (Process High Alarm) or at
and below which (Process Low Alarm) Alarm 2 is active.
To set press ( ) when displayed and follow the
instructions given in paragraph 3.4.
Defines the width of the hysterisis band in dewpoint
applied on the ‘safe’ side of the Alarm 2 level. Set in the
same manner as Alarm value.
Total value based upon integration of the input signal
using the time base set in the hygrometer settings.
Automatic display change if there
is no key activity after 3 seconds
Display change due to key activity