Alpha Communications STR QwikBus Скачать руководство пользователя страница 1

      

 

 
 

STR QwikBus™ 

 2 wire Color Video

 

Intercom System 

(with TT33, VSP333-2 and KMB3-AM) 

 

 

      

       

 

 
 

 

Installation, Programming, and  

User’s Manual 

 

 

 
 

 

 

 

Copyright

©

 2007-2013, Alpha Communications®, All Rights Reserved                                                    

AWD121

 

Rev. 1.3 09/2008 

Содержание STR QwikBus

Страница 1: ...R QwikBus 2 wire Color Video Intercom System with TT33 VSP333 2 and KMB3 AM Installation Programming and User s Manual Copyright 2007 2013 Alpha Communications All Rights Reserved AWD121 Rev 1 3 09 20...

Страница 2: ...12 The Matrix Wiring Custom Panel Buttons to the TT33 13 E56 E88 E120 Matrix Extenders 13 The IC2 database chip 14 Opening and Closing the VFS1500 1000 VH3033 Inside Stations 14 Programming the QwikBu...

Страница 3: ...the same 2 twisted wires Audio only stations are available as well and can be mixed and matched to suit your particular application QwikBUS COMPATIBLE INSIDE STATIONS FS1500 AUDIO STATION Voice Operat...

Страница 4: ...l be installing a larger number of entrances please contact Alpha Communications for design assistance Modular Panel STR modular panels are available in White Titanium and Dark Brown and are usually u...

Страница 5: ...ective wire diameter This will cause interference problems Do NOT install any unused additional wires with open ends Never connect the shield from a cable or connect the shield from one cable to anoth...

Страница 6: ...nnected to the TSMB3 T ON For more information refer to Page 10 Dipswitch Settings Be sure that the End of Line Jumpers are used on the camera circuit board and in the last monitor on each riser If th...

Страница 7: ...If the door strike is connected to the TSMB3 T ON as shown at Entrance 1 For more information refer to Page 10 Dipswitch Settings Be sure that the End of Line Jumpers are used on the camera circuit b...

Страница 8: ...onnected to the TT33 T ON For more information refer to Page 10 Dipswitch Settings Be sure that the End of Line Jumpers are used on the camera circuit board and in the last monitor on each riser If th...

Страница 9: ...g Entry For more information refer to Page 10 Dipswitch Settings Be sure that the End of Line Jumpers are used on the camera circuit board and in the last monitor on each riser If the last unit on a r...

Страница 10: ...outside power sources Many installers run the cable the easiest way and this unfortunately is usually by running the wire in a conduit or small enclosure right along side AC power lines near fluoresce...

Страница 11: ...r T Tapping to connect monitors from a riser as this will cause changes in the riser electronic characteristics which may cause signal degradation and poor video quality However when it is necessary t...

Страница 12: ...style or TT33 Custom style assign this code as shown in the chart below When a Door Strike is used It can be connected locally to the TSMB3 Modular style panels or TT33 Custom style Panels T terminal...

Страница 13: ...servation cameras set as camera 3 4 5 When a visitor rings from Entrance 1 camera 1 will come on the monitor to display the visitor but the resident can also cycle through all five cameras by pressing...

Страница 14: ...Usually these jumpers are supplied on all the monitors and camera boards and must be removed if the unit is not the last camera or monitor connected to the BUS line If there is only one camera used or...

Страница 15: ...ctronics are built into the TT33 and you must run wires to assign each button to a position in a matrix The chart to the left shows an example of how a 15 button panel could be connected using combina...

Страница 16: ...ecific entry Arrows indicate mounting screws NOTE Special Tool shown above is required for opening VFS FS panels as well as servicing Modular Entry Panels Part 13510 If you have to replace a TSMB3 or...

Страница 17: ...ove Dipswitch 1 at Speaker Microphone to OFF position Normal Operating Mode Programming Indoor Stations for Parallel Operation You can program up to 4 stations to ring with each pushbutton either for...

Страница 18: ...method 1 Connect the TT33 or TSMB3 Speaker Mic unit to BUS power and plug in programming cable to the J1 terminals indicated by the blue arrow 2 Move Dipswitch 1 to ON programming mode 3 Plug in othe...

Страница 19: ...ystem will exit programming mode The calling station will now ring the second station when that numeric button is pressed 3 Repeat this procedure for all units being called from the first station then...

Страница 20: ...one to OFF position Normal Operating Mode Programming Indoor Stations for Parallel Operation You can program up to 4 stations to ring with each pushbutton either for a residential system or multiple s...

Страница 21: ...ect the TT33 or TSMB3 Speaker Mic unit to BUS power and plug in programming cable to the J1 terminals indicated by the blue arrow 2 Move Dipswitch 1 to ON programming mode 3 Plug in other end of the c...

Страница 22: ...ift the handset and wait until the red LED and busy tone stop make sure the handset hasn t been called shortly before otherwise lift handset and hang up again to stop communication 2 Now you can liste...

Страница 23: ...ne make sure the station hasn t been called shortly before otherwise press the ON OFF button twice to stop communication 6 To hear the next ringtone continue keeping the LIGHT button depressed and pus...

Отзывы: