background image

14112012

MODEL 

MODEL 

MODEL

KIP-30-B1/FLB-30  KIP-30-W1/FIN-30 KIP-30-W3/FIN-30-3

KIP-45-B1/FLB-45  KIP-45-W1/FIN-45 KIP-45-W3/FIN-45-3

KIP-60-B1/FLB-60  KIP-60-W1/FIN-60 KIP-60-W3/FIN-60-3

KIP-80-B1/FLB-80  KIP-80-W1/FIN-80 KIP-80-W3/FIN-80-3

KIP-30-B3/FLB-30-3

KIP-45-B3/FLB-45-3

KIP-60-B3/FLB-60-3

KIP-80-B3/FLB-80-3

CONTROLS 

  CONTACTORS

F-1T 

  FL-402

F-2T 

  FL-303

F-2

Owner’s/Operator’s Manual

Sauna heater installation, wiring, operating instructions, trouble shooting, maintenance 

and guarantee.

IMPORTANT! This manual must be left with owner, manager 

or operator of Sauna after it is used by electrician!

Importer:

Almost Heaven Saunas

HC66, 465-A

Highway 219 North

Renick, West Virginia 24966

304-497-3991

Содержание KIP-30-B1/FLB-30

Страница 1: ...B3 FLB 30 3 KIP 45 B3 FLB 45 3 KIP 60 B3 FLB 60 3 KIP 80 B3 FLB 80 3 CONTROLS CONTACTORS F 1T FL 402 F 2T FL 303 F 2 Owner s Operator s Manual Sauna heater installation wiring operating instructions trouble shooting maintenance and guarantee IMPORTANT This manual must be left with owner manager or operator of Sauna after it is used by electrician Importer Almost Heaven Saunas HC66 465 A Highway 21...

Страница 2: ...2 ...

Страница 3: ...floor so that panel faces outward from room Punch out one of knockouts in roughin box and push rubber grommet provided into knockout hole Bring capillary tubing withsensingbulboutthroughgrommetandthrough stud wall so that capillary bulb is located 6 from ceiling inside Sauna room and as close to Sauna heater as possible taking care to avoid sharp bends in tubing to prevent damage to tubing and liq...

Страница 4: ...PACE ADEQUATE VENTILATION MODEL INPUT kW MIN HEIGHT FLOOR AREA SAUNA ROOM MIN SPACING FROM ADJACENT SURFACES INCHES Min Sq Ft Max Sq Ft Min Cu Ft Max Cu Ft KIP 30 B W FLB FIN 30 3 0 6 2 10 20 84 130 3 KIP 45 B W FLB FIN 45 4 5 6 2 16 30 100 210 3 KIP 60 B W FLB FIN 60 6 0 6 2 28 40 170 300 4 KIP 80 B W FLB FIN 80 8 0 6 2 40 65 250 425 5 Table 1 ...

Страница 5: ... 3 14 KIP 45 B3 FLB 45 3 4 5 12 5 208 3 14 KIP 60 B3 FLB 60 3 6 0 16 7 208 3 12 KIP 80 B3 FLB 80 3 8 0 22 2 208 3 10 1 2 3 1 2 3 KIP 30 B1 KIP 45 B1 KIP 60 B1 KIP 80 B1 FLB 30 FLB 45 FLB 60 FLB 80 240 V 1 PHASE HEATER HEATING ELEMENTS TIMER CONTACTOR THERMOSTAT LIMIT CONTROL LINE 1 LINE 2 GND GROUND Internal wiring only 1 2 3 1 2 3 KIP 30 B3 KIP 45 B3 KIP 60 B3 KIP 80 B3 FLB 30 3 FLB 45 3 FLB 60 3...

Страница 6: ...er with 90º connector Connect to terminals 1 and 2 and connect ground wire to lug marked ground Cover plate under heater must be removed first Note If connection to heater will be made at a later time bring flex into Sauna room 4 6 from floor and leave 3 of flex for hookup can be cut to right length later Before testing heater fill rock cavity with igneous stones provided with heater and fasten me...

Страница 7: ...trol to provide protection for light From control to heater provide seal tight flex conduit for wire and connect to junction box at back of heater with 90º connector Connect to terminals 1 and 2 and connect ground wire to lug marked ground Cover plate under heater must be removed first Note If connection to heater will be made at a later time bring flex into Sauna room 4 6 from floor and leave 3 o...

Страница 8: ...res or shorts The circuit breaker has been factory tested and if it is shorted out it will be responsibility of the electrical contactor to replace it Note If connection to heater will be made at a later time bring flex into Sauna room 4 6 from floor and leave 3 of flex for hookup can be cut to right length later Before testing heater fill rock cavity with igneous stones provided with heater and f...

Страница 9: ...al and separate ground Use 90 C copper wire from contactor to control and from control to room light Also use 90 C copper wire from contactor to Sauna heater within seal tight flex conduit and connect to junction box at back of heater with 90 connector Connect to terminals 1 2 3 and connect ground wire to lug marked ground Cover plate under of heater must be removed first Important Follow wiring i...

Страница 10: ...he first 1 to number 2 or 3 on the dial Then turn backward to the large 1 until a click is heard Leave knob at the setting and Sauna will operate for 1 hour before shutting off automatically Allow at least 30 minutes for room to heat up to an average Sauna temperature Note If you set timer past first 1 timer will not come on until the time set has elapsed The 60 min timer is quiet It does not tick...

Страница 11: ... person for further help NOTE A ground fault interrupter GFI should not be installed in and does not belong in a Sauna If used the breaker will trip and damage could result C If sauna heater operates but sauna room does not come up to sauna temperature 160 185ºF normal sauna temperature 1 You must allow at least 30 minutes for Sauna heat up time 2 Is Sauna thermometer located 6 from ceiling and is...

Страница 12: ...o change 5 times per hour Sauna shall be provided with intended ventilations as required per the local code authorities K LIGHT should be wall mounted vapor proof type located 6 from ceiling L ACCESSORIES bucket dipper and thermometer are essential Thermometer should be placed over the Sauna heater 6 from ceiling for correct temperature reading Other accessories such as hygrometer sand timer brush...

Страница 13: ... element 6 Slothead screw 7 Bottom grille 8 Stone compartment assembled frame 9 Electrical casing assembled 10 Plate 11 Screw 12 Tapping screw 13 Rating plate 14 Slothead screw 15 Slothead screw 16 Hexagon nut 17 Thermostat 18 Timer 19 Terminal strip USA 20 Strip fixing screw USA 21 Base plate 22 Screw 23 Bracket 24 Slothead screw 25 Slothead screw 26 Overheating limiter switch 27 Contactor USA 28...

Страница 14: ...ily cleaned concrete ceramic tile or a poured type of flooring When this is provided the Sauna can be easily cleaned and kept in a sanitary condition with little effort A carpet is NOT recommended for a Sauna A carpet becomes a prefect breeding ground for bacteria in the moist conditions of a Sauna and a carpet promotes the spread of foot diseases such as athlete s foot For the same reasons wooden...

Отзывы: