background image

 
 

 

Grayson Sauna 

Installation &  

Owner’s Manual

 

 

 

 

Revised February 2017

 

Содержание Grayson

Страница 1: ...Grayson Sauna Installation Owner s Manual Revised February 2017...

Страница 2: ...n integral floor platform Your sauna can be assembled on any surface that is firm and flat including concrete ceramic vinyl laminate or tile Installation on a carpeted surface is not recommended ASSEM...

Страница 3: ...loor riser Using 2 screws Draw the corners tight by angle screwing the corners together NOTE One side of each rail is pre drilled After lining up the rails and prior to screwing them to gether it is s...

Страница 4: ...edges and top edges align evenly Attach Wall Sections A and B ILLUSTRATION 1 The 8 wall sections A H will be positioned in the grooves of the completed wall support section as shown A B C D E F G H C...

Страница 5: ...ach to Wall Section D by way of the tongue and groove profile but will not be fastened with screws Position Wall Section E 10 Position WINDOW SECTION F Position Window Section F on the right front of...

Страница 6: ...to the filler strip previously attached to Window Section F Position Door Section H 14 Attach WALL CONNECTOR Find the pre drilled wall connector Place the wall connector on the top of the front wall e...

Страница 7: ...the groove of the other Measure around perimeter before fas tening to be sure distance from edge is equal NOTE Finished side of Roof Sections are to face the interior of the sauna with battens facing...

Страница 8: ...nch will overlap two wall sections on each side of the sauna Attach Lower Bench Attach Roof Trim pieces 19 Attach TRIM Find the package of 4 Roof Trim pieces and attach to the raw edge of the Roof Sec...

Страница 9: ...t Find the cord coming from the light switch and drill a small hole in Wall Section C to insert the Light Cord through so it comes through to the outside of the sauna 26 Mount POWER SUPPLY Use provide...

Страница 10: ...y vary depending on where the sauna was purchased Install sauna stones in accordance with heater manufacturer instructions Typical wiring requirements for distances of up to 30 feet from the breaker b...

Страница 11: ...the two sections of the door knob and insert the thread through the hole in the door Tighten so that handles are snug to glass NOTE Hand tighten only and be sure rubber gas ket is between knob and gla...

Страница 12: ...e vent located toward the top of the sau na It is important to have adequate fresh air flowing through the sauna and this flow can be adjusted with the movable vent cover TRADITIONAL STEPS IN TAKING A...

Отзывы: