5. EQUIPMENT ARRIVAL/INSPECTION

If there are any shortages, discrepancies or damage to your product upon delivery, please immediately contact Almeco.

6. SAFETY INFORMATION

• 

Installation, commissioning and electrical installation should only be performed by trained service personnel and in 

  accordance with the latest IEE regulations.

• 

This booth is supplied with an earth fixing at the back of the base section. 

• 

PLEASE USE THIS EARTH POINT IN ALL INSTANCES.

• 

Designers, manufacturers or operators are responsible for proper and safe installation as well as for safe operation. 

NEVER

USE THIS PRODUCT WITHOUT EXTRACTION CONNECTED.

• 

Safety features e.g. inlet guards, are not to be dismantled, circumvented or made inoperative.

Before using the JetBlack Safety Cleaning Booth

Electrical Safety

• 

The Booth supply cable should be checked for nicks and cuts. The cable should be regularly checked to ensure that it is in 

good condition.

• 

Ensure that the correct supply voltage is available. Check the rating plate below the isolator, on the back of the Booth, 
before connection.

• 

It is recommended that the unit be hard wired to an electrical supply that is surge protected and in compliance with local
codes. 

• 

Check the base Earth point (located at the rear) is in place and undamaged.

• 

Check that any plugs are suitable, undamaged and connected.

• 

The only serviceable part within the JetBlack Safety Cleaning Station is the filter element. 

• 

The only serviceable parts within the extractor are the filter collection bag, and the main canister filter.

General Safety

• 

Don’t use a pressure washer or steam washer to clean the Booth, extractor or Cleaning Station.

• 

Always switch off the main Booth electrical supply before cleaning and always isolate before servicing.

• 

EAR, EYE & RESPIRATION PROTECTION SHOULD BE USED AT ALL TIMES WHILST OPERATING THE BOOTH.

• 

Always direct air from the Cleaning Station away from your eyes, ears and face.

• 

The Cleaning Station has a thermal shut-off device for safety purposes. Prolonged use may cause the unit to shut-off. In this 
case, switch the unit off and wait for a few minutes before re-use.

• 

Don’t remove any guarding or the flexible hose at any time.

• 

Don’t allow objects to pass through the guard whilst the fan is rotating.

J

ET

B

LACK

 S

AFET Y 

- C

LEANING 

B

OOTH

Содержание JetBlack Safety Cleaning Booth

Страница 1: ...www almeco eu DRYING SOLUTIONS JETBLACK SAFETY CLEANING BOOTH Including Indoor Outdoor versions Installation Operation and Maintenance instructions...

Страница 2: ...mation 3 2 Cleaning booth overview 3 3 Main features and components 3 4 Outline drawings 5 5 Equipment arrival inspection 6 6 Safety information 6 7 Installation procedures 7 8 General operation 8 9 S...

Страница 3: ...wer or extractor All removed materials are either collected in the extractor or can be directly connected into a client s existing extraction system DO NOT USE THIS PRODUCT WITHOUT EXTRACTION CONNECTE...

Страница 4: ...eu Rain cover for extractor unit Outdoor Version Features Rain cover for main booth enclosure Internal Features for both Internal and External models LED Light On Off Switch PIR Sensor Cleaning Stati...

Страница 5: ...5 ALMECO nv Air and water technologies Royennestraat 51 B 7700 Moeskroen info axongroup com www almeco eu 4 OUTLINE DRAWINGS Indoor version Outdoor version JETBLACK SAFETY CLEANING BOOTH...

Страница 6: ...eck the rating plate below the isolator on the back of the Booth before connection It is recommended that the unit be hard wired to an electrical supply that is surge protected and in compliance with...

Страница 7: ...ed and pre wired Unpack the consignment and position the main Booth assembly in place Remove 4x Black Transport brackets from the base Fit the 4x M16 feet and level Fix anchor brackets feet via knock...

Страница 8: ...ep into the Booth and close the door fully The interior light and the extractor will turn on automatically The Cleaning Station can now be used Press the touch pad to operate the Cleaning Booth This i...

Страница 9: ...uations and flicker in public low voltage supply system Cleaning Station Maintenance and Service The following points must be observed when performing any maintenance or service operations to the Clea...

Страница 10: ...hose Air leaks in system Check replace damaged hose and clips Irregular Excessive Noise Blockage in air ducting Check all ducting and air delivery devices for blockages damage and replace as necessar...

Страница 11: ...11 ALMECO nv Air and water technologies Royennestraat 51 B 7700 Moeskroen info axongroup com www almeco eu JETBLACK SAFETY CLEANING BOOTH 11 WIRING DIAGRAMS...

Страница 12: ...12 ALMECO nv Air and water technologies Royennestraat 51 B 7700 Moeskroen info axongroup com www almeco eu JETBLACK SAFETY CLEANING BOOTH...

Страница 13: ...e The following test procedure will guide the LEV service provider into making a full true correct commissioning report 1 Ensure that the Booth is installed as per section 7 Check all bags filters hos...

Страница 14: ...duct for damage Check filters for condition damage Check waste collectors damage condition Empty waste col lectores damage condition Empty dust collection bags Comments 1 2 3 4 5 6 7 8 9 10 11 12 CLE...

Страница 15: ...collectors damage condition Empty waste col lectores damage condition Empty dust collection bags Comments 35 36 CLEANING STATION FILTER CHANGE 37 38 39 40 41 42 43 44 45 46 47 48 CLEANING STATION FILT...

Страница 16: ...fter this period This is considered to be normal wear associated with the use of the motor and therefore not covered under the warranty Spares can be purchased from Almeco Work carried out under the w...

Отзывы: