Fast Ethernet PoE+ Unmanaged Switch

 

User Manual 

Version 1.0– August 2013 

 

 

POEFE8TV3 

 

Содержание POEFE8TV3

Страница 1: ...Fast Ethernet PoE Unmanaged Switch User Manual Version 1 0 August 2013 POEFE8TV3...

Страница 2: ...ements 3 1 Introduction 6 2 Checklist 6 3 Installation 6 3 1 Installation Method 7 3 2 Desktop or Shelf Installation 7 3 3 Rack Installation 7 4 Powering on the Switch 9 5 LED Description 9 6 Network...

Страница 3: ...this device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for...

Страница 4: ...y it assumes a basic working knowledge of LANs Local Area Networks The unit must be connected to an earthed grounded outlet to comply with international safety standards Do not connect unit to an A C...

Страница 5: ...replace it at once Proper space for heat dissipation is necessary to avoid any damage caused by device overheating The ventilation holes on the device are designed for heat dissipation to ensure that...

Страница 6: ...P Phone infrastructure Features Supports PoE power up to 30W for each PoE port At full load the POE switch will support 30W on 4 ports 18 75W on 8 ports Supports PoE power up to 150W for all PoE ports...

Страница 7: ...an be found at the back of the POEFE8TV3 Leave at least 10cm of space at the front and rear of the switch to ensure adequate ventilation 3 2 Desktop or Shelf Installation When installing the switch on...

Страница 8: ...POEFE8TV3 User Manual Alloy Computer Products Pty Ltd Copyright 2013 Fig 2 Rack Mount kit installation Fig 3 Mounting the switch...

Страница 9: ...cription LED Colour Function Power On Appropriate power is supplied Off Power is not available LINK On A valid link is established Blink Traffic is present on port Off No link established POE On PD Po...

Страница 10: ...ers or hubs Each device requires an unshielded twisted pair UTP cable with RJ 45 connectors at both ends Use Category 5 or better for 100BASE TX connections and Category 3 or better for 10BASE T conne...

Страница 11: ...imum 100m EIA TIA 568 100 STP maximum 100m Transfer Method Store and Forward Switching Capacity 1 6G MAC Address Table 2K Frame Filtering and Forward Rate 10Mbps 14880pps 100Mbps 148800pps POE Up to 3...

Страница 12: ...e the connected device is turned on and working properly The cable must be less than 100 meters long 328 feet Check the port on the attached device and cable connections for possible defects Replace t...

Страница 13: ...signal MDI X signal 1 TX RX 2 TX RX 3 RX TX 4 not used not used 5 not used not used 6 RX TX 7 not used not used 8 not used not used Below is a diagram of a typical straight through and cross over cab...