Allmatic CT3IND Скачать руководство пользователя страница 1

ITA

 

 ENG

 

 FRA

 

 ESP

 

 DEU

 

 POR

 

1 / 10

 

6

-

1622598    REV.3      23/09/2020

 

C

om

pa

tible

 fr

om

 fir

m

w

ar

ve

rs

ion

 B

3TS

01

 

CONTROL UNIT CT3IND

 

Programmable Control board for sliding gates

 

 

Manual for installation

 

C

om

pa

tible

 fr

om

 fir

m

w

ar

ve

rs

ion

 B

3TS

01

 

Содержание CT3IND

Страница 1: ...ESP DEU POR 1 10 6 1622598 REV 3 23 09 2020 Compatible from firmware version B3TS01 CONTROL UNIT CT3IND Programmable Control board for sliding gates Manual for installation Compatible from firmware ve...

Страница 2: ...sense that enables the detection of possible obstacles along the run furthermore it has a motor protector that enables to protect the motor in case of over current In each control unit it is installe...

Страница 3: ...under the condition of the control unit not enabled to the nor mal functioning i e stop activated thermal menu activated The outputs RED 11 12 GREEN 13 14 and ALARM 15 16 are dry contacts 5A max to w...

Страница 4: ...g the menu and 16 36 35 34 Connect the clamp 36 of the control unit to the clamp of power supply for the photocell s transmitter Connect the clamp 35 of the control unit to the clamp of power supply f...

Страница 5: ...dges are not used jumper the inputs and set the safety edge in the menu the type mechanical edge Press the key P1 The automation must open YES Press the key P3 The automation must close NO Invert the...

Страница 6: ...enu of the transmitters 1 press the key P1 2 on the display the writing appears at this stage execute the following procedure Learning turned out well Press the key of the transmitter to learn The dis...

Страница 7: ...sensitivity increases a lower force will be necessary to stop the motor The more the values increase the more the sensitivity decrease a higher force will be necessary to stop the motor 1 99 OFF Inve...

Страница 8: ...ervention of the photocell during the opening the movement is stopped until the obstacle has been removed in order to continue then the movement in opening In case of intervention of the photocell dur...

Страница 9: ...Motor output 230Vac single phase 800W Max 400 Vac THREE PHASE 1 5KW Max current limited to 10A cos 0 8 Flashing light output 230 Vac 60W MAX for fix light without self blinking Courtesy light output...

Страница 10: ...na Belluno Italy Via dell Artigiano n 1 Z A Tel 0437 751175 751163 r a Fax 0437 751065 www allmatic com E mail info allmatic com DISPOSAL OF THE PRODUCT This product is an integral part of the automat...

Отзывы: