B1VR PROX
Control unit for 1 motor with anemometer input
1. Introduction
The control units of the series B1VR PROX are devices suitable to carry out the activation and the control of awnings and shutters in a simple and
complete way, designed to meet any requirement. This product can control a 230Vac motors up to 500W (max) of power. The B1VR PROX control
units, if equipped with the radio receiver module, use the innovative system of rolling code decoding, easy and intuitive on the installation. In the
extractable memory it is possible to memorize up to 1000 channel (8000 with optional memory) of the series Birol® and CLARUS. Includes an input for
a wind sensor (WIN Allmatic series), which allows to close the automation in case of danger situation, due to an excessive velocity of the wind. There
are also 2 separate inputs for the opening and the closing buttons and for programmed opening (“clock function” see section 7). In case where the
radio receiver is not installed, the presence of the buttons is necessary to control the automation.
WARNING: DO NOT INSTALL THE CONTROL UNIT WITHOUT READING THE INSTRUCTIONS BEFORE!!
2. Description
3. Electrical connections
Installation and advices
•
Connect the motor to the terminal boards 8,9,10 respecting
the scheme and the polarity of the motor (open =unrolling
awning, close= rolling up awning).
•
Connect the buttons open and close of the motor to the
terminal boards 5,6,7 respecting the scheme and trying to
separate as much as possible these cables from those
of the line tension and of the motor.
•
Connect the clock for motor to terminal boards 5 and 6 (refer
to the sections 7).
•
Connect the wind sensor to the terminal boards 4 and 5.
Also in this case, avoid to make the cable slide near to
to the cables of the line tension and of the motor, in
order to insulate it from external interferences. For a
connection scheme of an anemometer with more control
units, refer to the section 9.
•
Connect the cables of the line tension 230Vac to the terminal
boards 11, 12.
Preliminary checks
Move manually the automation in the middle of stroke, set the
wind trimmer about at minimum and move manually the
anemometer, be sure that the automation closes when the wind
allarm appear. If the automation opens check the connections of
the motor.
Connections wind sensor
Dip switch for the
selection of the functions
Led of diagnosis of
the radio disturb
Jumper for wind
sensor expansion
Adjustment threshold
of wind alarm velocity
Radio receiver module
Learning/alarm led
Learning
button
Inputs fuse
F 50 mA
Line fuse
F 6.3 A
Transmitters
memory
WIN S:
Connect cables on inputs N°4 and
N°5 of the terminal board B1VR.
KAIROS S:
Connect cables on inputs N°4 and
N°5 of the terminal board B1VR.
NOTE: connection cables have no polarity.
NOTE: the control unit is also compatible with WIN EX sensor.