1

Non contact infrared thermometer

with APP function

User manual

1

Introduction

Compact, rugged and easy to use. Just aim and push the button, read

current surface temperatures in less than a second. Safely measure

surface temperatures of hot, hazardous or hard-to-reach objects without

contact.

How it works

Infrared thermometer measures the surface temperature of an object. The

unit’s optics sense emitted, reflected, and transmitted energy which is

collect and focused onto a detector. The unit’s electronics transmitted

energy which is display on the unit. For increased ease and accuracy the

laser pointer makes aiming even more precise.

Cautions

Infrared thermometer should be protected for the following:

--EMF(electro-magnetic fields) from arc welders, induction heaters.

--Thermal shock(cause by large or abrupt ambient temperature changes

allow 1 hours for unit to stabilize before use).

--Do not leave the unit on or near objects of high temperature.

Warning

Do not point laser at eye or indirectly off reflective surfaces.

1. When take measurement, point thermometer toward the object to be

measured and hold the yellow trigger. The object under test should

be large than the spot size calculated by the field of view diagram.

2. Distance

spot size: As the distance from the object increase, the

spot size of measuring area becomes large.

3. Field of view: Make sure the target is larger than the unit’s spot size.

The smaller the target the close measure distance. When accuracy is

critical, make sure the target is at least twice as large as the spot

size.

4.

Emissivity: Most organic materials and painted or oxidized surfaces

have an emissivity of 0.95. Inaccurate readings will result from

measuring shiny or polished metal surfaces. To compensate, cover

the surface to be measured with masking tape or flat black paint.

Measure the tape or painted surface when the tape or painted reach

the same temperature as the material underneath.

5. When changing from low temperature environment to high

temperature environment or from high temperature

environment to low temperature environment, please wait for

30 minutes, and then measure after the temperature of the

machine is balanced with the ambient temperature.

2

Quick start instruction

1. Remove the battery cover screw with a screwdriver, and then slide

out the battery door, install battery correctly. And Put back to the

battery door screws .Pull the trigger, LCD display reading

battery icon. Release the trigger and the reading will hold for 10

seconds.

LCD display:

Display area:36.4

×

34.6(mm)

character 13.3mm high.

A Data Hold

B Main dislplay value

C Memory storage

D Maximum

E Continuous measurement

F K type temperature symbol (this unit Without this feature)

G

High temperature alarm temperature

H Alarm of high temperature prompt

I Alarm of Low temperature prompt

J Low temperature alarm temperature

K Battery voltage Low

L Backlight symbol

M Additional features

N

Minimum

O

Average

P The maximum and the minimum difference

Q Temperature of the unit

R Laser pointer turn on prompt

Emissivity symbol

T Measuring the symbol

2. Locating a hot spot aim the thermometer outside the area of interest,

then scan across with up and down motions until you locate the hot

spot.(please turn on the laser to for accurate measuring)

Содержание HP-1500-APP

Страница 1: ...s the spot size 4 Emissivity Most organic materials and painted or oxidized surfaces have an emissivity of 0 95 Inaccurate readings will result from measuring shiny or polished metal surfaces To compensate cover the surface to be measured with masking tape or flat black paint Measure the tape or painted surface when the tape or painted reach the same temperature as the material underneath 5 When c...

Страница 2: ... using for a long time Note 1 Do not use solvent to clean lens 2 Do not submerge the unit in water 3 Emissivity will back to the initial value 0 95 after replacing battery Should adjust again when use 4 Specifications Attached list Applicable Emissivity for Different Material For reference only Material Emissivity Material Emissivity Asphaltum 0 90 to 0 98 Textile Black 0 98 Beton 0 94 Human Skin ...

Страница 3: ...unt password login Set up an account and password through registration and log in with the set account password 2 Third party application authorized login currently supports WeChat and facebook authorized login Forgot Password When the user forgets the password he can reset the password through this setting 1 Enter the account that needs to reset the password 2 Send verification code Click the Sen...

Страница 4: ... place the infrared thermometer can be turned on by remote control and the distance in the open place can reach 80m 2 Measurement button press the button the infrared thermometer can carry out for continuous measurement 3 Stop button press the button to stop the continuous measurement And stop recording data 4 Reset button press the button to reset the temperature value of the main interface 5 6 7...

Страница 5: ...me Feedback With any comments or suggestions you can tell us through this function to help us improve the product and make the product better After receiving the feedback we will handle it as soon as possible The problem should be described in detailed as much as possible and the corresponding picture can be added to the APP problem In order to supplement the description more clearly the programme...

Страница 6: ...L COM P S To make sure you can receive immediate solution and your requests processed quickly please email us with these information 1 Order Number 2 Platform of Your Purchase 3 Full Model Number 4 Description of the Problem Attaching videos or photos can help us troubleshoot the problems even faster ...

Страница 7: ...diate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is enc...

Отзывы: