Temperature register
The temperature is implemented with Presence_Inq=1 (available) and
ON_OFF [6] always ON according to IIDC V1.31:
From -10 °C to +65 °C the temperature accuracy is: +1.5 °C / -2.0 °C
Register
Name
Field
Bit
Description
0xF0F0082C
TEMPERATURE Presence_Inq
[0]
Presence of this feature:
0: N/A
1: Available
Abs_Control
[1]
Absolute value control
O: Control with value in the value field
1: Control with value in the absolute value
CSR
If this bit=1 the value in the value field has
to be ignored.
---
[2..4]
Reserved
One_Push
[5]
Write 1: begin to work (self cleared after
operation)
Read: Value=1 in operation
Read: Value=0 not in operation
If A_M_Mode=1, this bit is ignored
ON_OFF
[6]
Write: ON or OFF this feature
Always 1
0: OFF
1: ON
A_M_MODE
[7]
Write: set mode
Read: read current mode
0: MANUAL
1: AUTO
---
[8..19]
Reserved
Value
[20..31] Temperature at the present time (read only)
Read out temperature value and divide by
10: this is the temperature at sensor in
degree Celsius.
Info:
50 °C at sensor is approximately 45 °C
at camera housing. So never run the camera
with more than 50 °C at sensor.
•
min. displayed temperature: -55 °C
•
max. displayed temperature: 150 °C
•
Increment: 0.25 °C/step
Table 127: CSR: