508298-01
Page 47 of 55
Issue 2219
A96DF1E110C20S Performance (Less Filter)
External
Static
Pressure
in. w.c.
Air Volume / Watts at Different Blower Speeds
High
Medium-High
Medium
Medium-Low
Low
cfm
watts
cfm
watts
cfm
watts
cfm
watts
cfm
watts
0.00
2115
669
1895
466
1710
356
1605
285
1415
209
0.10
2090
686
1845
476
1670
368
1570
299
1380
217
0.20
2060
701
1790
487
1630
375
1520
315
1320
222
0.30
2020
711
1760
498
1590
393
1470
324
1280
236
0.40
1980
734
1715
511
1545
403
1420
342
1220
247
0.50
1935
740
1690
525
1500
418
1370
347
1170
264
0.60
1895
749
1625
536
1460
423
1335
358
1110
269
0.70
1830
738
1600
548
1410
438
1280
367
1080
286
0.80
1765
723
1550
564
1370
456
1240
387
1010
290
NOTE
: All air data is measured external to unit without filter (not furnished - field provided)
Allowable Heating Speeds
Model
Red
Yellow
Blue
Brown
Black
045
Allowed
Factory Setting
Allowed
Not Allowed
Not Allowed
070
Allowed
Factory Setting
Allowed
Not Allowed
Not Allowed
090
Allowed
Factory Setting
Allowed
Allowed
Not Allowed
010
Allowed
Allowed
Allowed
Factory Setting
Not Allowed
Table 20.
Allowable Circulation Speeds
Model
Red
Yellow
Blue
Brown
Black
All Models
Factory Setting
Not Allowed
Not Allowed
Not Allowed
Not Allowed
Table 21.
Содержание A96DF1E
Страница 32: ...508298 01 Page 32 of 55 Issue 2219 Figure 50 Trap Drain Assembly Using 1 2 PVC or 3 4 PVC ...
Страница 38: ...508298 01 Page 38 of 55 Issue 2219 045 B12 070 B16 090 C16 110 C20 Figure 57 Typical Wiring Diagram ...
Страница 51: ...508298 01 Page 51 of 55 Issue 2219 Troubleshooting Heating Sequence of Operation ...
Страница 52: ...508298 01 Page 52 of 55 Issue 2219 Troubleshooting Heating Sequence of Operation continued ...
Страница 53: ...508298 01 Page 53 of 55 Issue 2219 Troubleshooting Cooling Sequence of Operation ...
Страница 54: ...508298 01 Page 54 of 55 Issue 2219 Troubleshooting Continuous Fan Sequence of Operation ...