OPERATION
High Altitude
The manifold pressure, gas orifice and pressure switch
may require adjustment or replacement to ensure proper
operation at higher altitudes. See Table 14 for manifold
pressures and Table 15 for pressure switch and gas
conversion kits.
For safety, shut unit OFF and remove manometer as
soon as an accurate reading has been obtained. Take
care to replace pressure tap plug.
WARNING
Manifold Pressure Settings
1
This is the only permissible derate for these units.
2
Natural gas high altitude orifice kit required.
3
A natural to L.P./propane gas changeover kit is necessary to convert this unit. Refer to the changeover kit installation instruction for the
conversion procedure.
NOTE:
Units may be installed at altitudes up to 4500 ft. above sea level without modifications.
Table 14
High Altitude Pressure Switch and Gas Conversion Kits
Table 15