P
OWER
OVER
E
THERNET
C
OMMANDS
POWER
-
INLINE
USAGE
-
THRESHOLD
power-inline usage-threshold
Overview
This command sets the level at which the switch will issue a message that the
power supplied to all Powered Devices (PDs) has reached a critical level of the
nominal power rating for the switch. The level is set as a percentage of total
available power.
The
no
variant of this command resets the notification usage-threshold to the
default (80% of the nominal power rating).
Syntax
power-inline usage-threshold <
1-99
>
no power-inline usage-threshold
Default
The default power usage threshold is 80% of the nominal power rating
Mode
Global Configuration
Usage
Use the
command to configure SNMP notification. An
SNMP notification is sent when the usage-threshold, as configured in the example,
is exceeded.
Examples
To generate SNMP notifications when power supplied exceeds 70% of the nominal
power rating, use the following commands:
awplus#
configure terminal
awplus(config)#
snmp-server enable trap power-inline
awplus(config)#
power-inline usage-threshold 70
To reset the notification threshold to the default (80% of the nominal power
rating), use the following commands:
awplus#
configure terminal
awplus(config)#
no power-inline usage-threshold
Related
Commands
power-inline
Parameter
Description
<
1-99
>
The usage-threshold percentage configured with this
command.