background image

AT-S80 Version 2.3.1 Software Release Notes

PN 613-001276 Rev B

2

Allied Telesis, Inc.

Operational Issues

ˆ

Boot Time. AT-S80 software takes the following amount of time to boot depending on the 
version of firmware you have loaded onto your switch:

Table 1: Approximate Boot Time

What’s New in Version 2.3.1

Resolved Issues

ˆ

None

Known Issues

ˆ

None

Operational Notes

ˆ

The length of the RADIUS shared key is currently limited to 19 characters.

ˆ

When setting the Bandwidth Control Ingress Limit Rate, you must select a threshold level of 
L/M/H for all ports. These levels approximately correspond to the following data rates based 
on a packet length of 1518 bytes:
— High: 3000 packet/s
— Medium: 500 packet/s
— Low: 100 packet/s 

New Feature

ˆ

The maximum 802.1x/Radius user name length has been increased to 64 characters.

REVISION HISTORY

Version 2.3.0

See Software Feature History

Version 2.2.0

Hardware Features

ˆ

None

Version

Approximate Boot Time

1.0.0.49

48 seconds

2.0.0

113 seconds

2.1.0

210 seconds

2.2.0

50 seconds

2.3.0

50 seconds

Содержание WebSmart AT-FS750/16

Страница 1: ... The AT FS750 16 and AT FS750 24 Fast Ethernet Smart Switch supports the following ATI SFP modules 100 MB SFPs AT SPFX 2 AT SPFX 15 1000 MB SFP AT SPSX AT SPLX10 AT SPLX40 AT SPZX80 Product Documentation For hardware installation and management instructions refer to the following guides on the Allied Telesis web site at www alliedtelesis com software AT S80 Management Software User s Guide Install...

Страница 2: ...y limited to 19 characters When setting the Bandwidth Control Ingress Limit Rate you must select a threshold level of L M H for all ports These levels approximately correspond to the following data rates based on a packet length of 1518 bytes High 3000 packet s Medium 500 packet s Low 100 packet s New Feature The maximum 802 1x Radius user name length has been increased to 64 characters REVISION H...

Страница 3: ...displayed the 100FX link on each port Applying PVID via Web Applying the certain PVID s to a port when using the web interface now succeeds and will result not in an error message Port Mirroring Port Mirroring is now working properly Version 2 1 0 Hardware Features None Known Issues The following issues were found in this release Default VLAN The Management port can be accessed from any VLAN and i...

Страница 4: ...7352 Retention of the 802 1x Dynamic VLAN password When using the Firefox browser you may now modify the 802 1x password without getting an error message 7073 Features History Version 2 3 0 Management access can now be restricted to the default VLAN VLAN 1 This feature is activated when you select ENABLE for the Management VLAN field on the VLAN Configuration web page If this field is set to DISAB...

Страница 5: ... Telesis Inc Static Multicast Address Table IGMP Snooping Bandwidth Control Ingress Egress Rate Limiting Port Based VLAN Destination MAC Filter Firmware Upgrade via HTTP 100FX SFP Support Statistics Charts in the Web interface 802 1X MAC Base 802 1X Local Dial In User Table ...

Страница 6: ...opriate menu tab Sales or Corporate Information You can contact Allied Telesis for sales or corporate information through our web site www alliedtelesis com Select your country from the list displayed on the website Then select the appropriate menu tab Where to Find Management Software Updates and Product Information Management software updates are on the Allied Telesis web site In addition the in...

Отзывы: