Chapter 1: Overview
37
PWR 1 and PWR 2 DC Power Connectors
The PWR 1 and PWR 2 connectors are for DC power supplies. You can
power the unit with one power supply or two power supplies for power
redundancy, which protects the device from power loss in the event a DC
power unit fails or loses power.
The switches support the following types of power sources:
AC/DC rectifiers
Un-interruptible power supplies
For power supply requirements, see “Power Supplies” on page 49.
Note
The AT-iMG008 Power Supply and Backup Unit from Allied Telesis
is not compatible with IE340 switches.